Page 1: ...Thermostatic Concentric Mixer Valve with Fixed Head Wall Arm Atmos Zinc Thermostatic Concentric Mixer Valve with Fixed Head Wall or Ceiling Arm Customer Care 0845 505 2211 TMV2 Approval property of T...

Page 2: ...8 liters per minute the appliance must be capable of raising the water temperature to a minimum of 52 C The water temperature at the inlet to the mixer valve must remain relatively constant when flow...

Page 3: ...a point not less than 25mm above the spill over level of the relevant bath shower tray or other fixed appliance A double check valve or similar MUST be fitted in the supply pipework to prevent back fl...

Page 4: ...hot and cold water pressures If this is not the case a flow controller disc with small holes can be fitted to the higher pressure supply to the valve This is best done by testing each one to find out...

Page 5: ...th Wall Arm Atmos Zone Concealed Valve with Wall Arm Atmos Zinc Concealed Valve with Ceiling Arm Atmos Zinc Consult the illustration below to make sure you check from the component list that all the p...

Page 6: ...water pressures to hot and cold are the same these disks do not need to be used CONCENTRIC VALVE SET UP 1 Your thermostatic concentric mixer valve is set up in the factory so that a shower hose can be...

Page 7: ...getting into the openings while fitting the pipework You should measure the distance between the outlets on the mixer valve you are fitting to determine the exact distance 3 Complete the fitting of t...

Page 8: ...nnecting the water supplies and checking the connections when running the shower and when the shower is off TRIM PLATE FITTING FOR Atmos Zinc Zone 1 The trim plate is fitted by pushing it onto the mix...

Page 9: ...arm drill a suitable 19mm hole through the wall NOTE When fitting to stud wall a bearer between the uprights maybe required 3 Remove fittings and nuts from end of arm and push arm through wall re fit...

Page 10: ...fit a cross bearer between two joists Drill suitable 19mm hole through ceiling See Fig 23 3 Remove fittings and nuts from end of arm and push arm through wall re fit washer and nut 4 Connect mixed wat...

Page 11: ...ew Then turning the splined shaft clockwise to decrease the temperature colder or anti clockwise to increase the temperature hotter when you have achieved a temperature of 38 C re assemble the tempera...

Page 12: ...the heating system F Hot water supply blocked or restricted G Pressure in excess of max recommended SUGGESTED ACTION Adjust the temperature control this is only a job for a suitably qualified person T...

Page 13: ...Showerhead Reduce simultaneous demand Check stop service valves are fully open Check if enough water pressure Fit reducing disc to outlet of valve Renew flow control cartridge see parts list COMPONEN...

Page 14: ...IT SPARE PARTS Atmos Zinc 1 Fixed Overhead ZLK 2 Wall Arm ZLJ 3 Ceiling Arm ZLI 4 Valve only 36HLW ZLD VALVE SPARE PARTS LIST 5 Fitting Kit 36HLW ZJK 6 Cartridge All in one ZJA 7 Square Cover Plate ZJ...

Page 15: ...14 ACCESSORIES KIT SPARE PARTS Atmos Zone 1 Fixed Overhead ZLS 2 Valve only 36HLW ZLG VALVE SPARE PARTS LIST 3 Fitting Kit 36HLW ZJK 4 Cartridge all in one ZJA 5 Cover Cover Plate ZJV 1 2 3 4 5...

Page 16: ...hout charge provided the product has been properly installed maintained and operated in accordance with the operating instructions This product must not be modified repaired or taken apart except by a...

Page 17: ...5 This guarantee applies to an original installation in accordance to our fitting instructions and does not cover previously installed products showroom displays etc or products that have been moved f...

Page 18: ...our part for death or personal injury resulting from our negligence 4 Except as stated above and to the fullest extent permitted by law all conditions warranties and representations whether express o...