12. FITTING THE WALL ARM FITTING

1.  Establish position of wall arm to suit users 

requirements (Fig 19).

2.  When fitting the wall arm drill a 19mm hole 

through the wall, you may require a suitable piece 

of wood to give the arm support behind the tiles or 

plasterboard.

3.  Remove fittings and nut from end of arm through 

wall, re-fit washer and nut.

4.  Connect wall arm to the pipework installed from 

the valve.

5.  When attaching the fixed showerhead make sure 

the sealing washer is in place and screw tight to 

seal the joint, again a flow controller can be fitted if 

required (Fig 20 & 21).

NOTE: The fitting of these items should be carried out 

by a competent person.

19

20

21

Summary of Contents for Atmos Select

Page 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Select 3 Way Thermostatic Concentric Mixer Valve with Riser Rail and Overhead...

Page 2: ...resystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTAN...

Page 3: ...1 HoseRetainingRing 1 FlowController 1 AllenKey 1 PressureBalanceKit 1 ScrewPack 3screws 3plugs 1 FittingInstructions 1 TMVRegistrationCard 1 Allen Key Pressure Balance Kit Screw Pack Fitting Instruc...

Page 4: ...quareWallOutlet 1 HandsetHeightAdjuster 1 1 5mHose Washers 1 FilterWashers 2 BlankingNut 1 FlowController 1 AllenKey 1 PressureBalanceKit 1 ScrewPack 3screws 3plugs 1 FittingInstructions 1 TMVRegistra...

Page 5: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Page 6: ...MUSTbefittedinthesupply pipeworktopreventback flow Thepressureatboththehotandcoldwater suppliestothemixervalveshouldbethesame andtheinstallershouldensurethattheflowisnot affectedbyothertapselsewherein...

Page 7: ...uldpointupwards n Themixervalveisdesignedtoworkatthesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto thehigherpressuresupplytothevalve Thisisbest doneb...

Page 8: ...accessorieswhicharenotsupplied Youshouldmeasurethedistancebetweentheoutlets onthemixervalveyouarefittingtodeterminethe exactdistance 4 Atthispointyoumaywishtofitthepipeworkand thewallarm seewallarmfit...

Page 9: ...shwiththetiles Fig5 NOTE Beforeassemblingthevalvecontrolsidentify allthepartsandcheckthatboththeredmarkingson thecontrolshaftofthethermostaticcontrolareinline 11 Fittheon offknobontothediverter thetop...

Page 10: ...RISERRAIL ROUNDSTYLE 1 Havingestablishedthepositionoftheriserrailso thattheshowerheadcanbecomfortablyreached whilstusingtheshower makesureanycablesand pipeworkarenotbehindthescrewholes Fig9 2 Removeen...

Page 11: ...he handsetwillnotfitintheheightadjusterwithoutthe doubleinterlockhoseattahced 13 10B FITTINGTHERISERRAIL SQUARESTYLECONT 1 Havingestablishedthepositionoftheriserrailso thattheshowerheadcanbecomfortabl...

Page 12: ...hearmsupportbehindthetilesor plasterboard 3 Removefittingsandnutfromendofarmthrough wall re fitwasherandnut 4 Connectwallarmtothepipeworkinstalledfrom thevalve 5 Whenattachingthefixedshowerheadmakesur...

Page 13: ...ets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly...

Page 14: ...evalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpres...

Page 15: ...toyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe productandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranypr...

Page 16: ...upplied 6 Servicechargesarebasedontheaccountbeing settledwhenworkiscomplete theengineerwill thenrequestpayment Ifthisisnotmadetothe serviceengineerorsettledwithintenworkingdays anadministrationchargew...