background image

11. FITTING THE DOUBLE INTERLOCK HOSE & HANDSET

1.   Connect one end of the double interlock hose to 

the outlet, making sure that the sealling washer is 

in place .

2.  Pass the doulbe interlock hose through the hose 

retaining ring then screw onto the handset using 

the washer. Carry out a leak test (Fig18).

3.   MX provide an eco flow controller with every 

handset they sell. This reduces the flow of water at 

high water pressures. If you require, fit between the 

handset and the hose. 

NOTE: It is the conical end of the double interlock 

hose which grips into the handset height adjuster. The 

handset will not fit in the height adjuster without the 

double interlock hose attahced.

13

10B. FITTING THE RISER RAIL (SQUARE STYLE CONT)

1.  Having established the position of the riser rail so 

that the showerhead can be comfortably reached 

whilst using the shower, make sure any cables and 

pipework are not behind the screw holes (Fig 13).

2.  Remove caps for the riser rail wall brackets, mark 

the position of the hose and drill plug and screw to 

fit the two wall brackets. Fix lower braket to wall 

(Fig 14).

3.  With the handset height adjuster on the left hand 

side, fit the hose retaining ring and then soap dish 

onto the bottom of the rail assembly. Replace the 

rail assembly onto the lower bracket. Fit top bracket 

to rail and screw wall and replace both end caps 

(Fig 15 & 16).

14

15

16

18

Round Style

Square Style

Summary of Contents for Atmos Select

Page 1: ...Fitting Instructions IMPORTANT This Step by Step guide should be retained after installation Atmos Select 3 Way Thermostatic Concentric Mixer Valve with Riser Rail and Overhead...

Page 2: ...resystemsuptoamaximumof5barrunning pressure Themixervalvemustnotbesubjectedto watertemperaturesabove80 C Thismixervalveis alsosuitableforthermalstorage unventedsystems andpumpedgravitysystems IMPORTAN...

Page 3: ...1 HoseRetainingRing 1 FlowController 1 AllenKey 1 PressureBalanceKit 1 ScrewPack 3screws 3plugs 1 FittingInstructions 1 TMVRegistrationCard 1 Allen Key Pressure Balance Kit Screw Pack Fitting Instruc...

Page 4: ...quareWallOutlet 1 HandsetHeightAdjuster 1 1 5mHose Washers 1 FilterWashers 2 BlankingNut 1 FlowController 1 AllenKey 1 PressureBalanceKit 1 ScrewPack 3screws 3plugs 1 FittingInstructions 1 TMVRegistra...

Page 5: ...dent method of isolating the shower should maintenance or servicing be necessary these valves SHOULD NOT restrict the flow DO NOT operate the shower outside the recommended temperatures and pressures...

Page 6: ...MUSTbefittedinthesupply pipeworktopreventback flow Thepressureatboththehotandcoldwater suppliestothemixervalveshouldbethesame andtheinstallershouldensurethattheflowisnot affectedbyothertapselsewherein...

Page 7: ...uldpointupwards n Themixervalveisdesignedtoworkatthesame hotandcoldwaterpressures Ifthisisnotthecasea flowcontroller discwithsmallholes canbefittedto thehigherpressuresupplytothevalve Thisisbest doneb...

Page 8: ...accessorieswhicharenotsupplied Youshouldmeasurethedistancebetweentheoutlets onthemixervalveyouarefittingtodeterminethe exactdistance 4 Atthispointyoumaywishtofitthepipeworkand thewallarm seewallarmfit...

Page 9: ...shwiththetiles Fig5 NOTE Beforeassemblingthevalvecontrolsidentify allthepartsandcheckthatboththeredmarkingson thecontrolshaftofthethermostaticcontrolareinline 11 Fittheon offknobontothediverter thetop...

Page 10: ...RISERRAIL ROUNDSTYLE 1 Havingestablishedthepositionoftheriserrailso thattheshowerheadcanbecomfortablyreached whilstusingtheshower makesureanycablesand pipeworkarenotbehindthescrewholes Fig9 2 Removeen...

Page 11: ...he handsetwillnotfitintheheightadjusterwithoutthe doubleinterlockhoseattahced 13 10B FITTINGTHERISERRAIL SQUARESTYLECONT 1 Havingestablishedthepositionoftheriserrailso thattheshowerheadcanbecomfortabl...

Page 12: ...hearmsupportbehindthetilesor plasterboard 3 Removefittingsandnutfromendofarmthrough wall re fitwasherandnut 4 Connectwallarmtothepipeworkinstalledfrom thevalve 5 Whenattachingthefixedshowerheadmakesur...

Page 13: ...ets 3 Overridethetemperaturestopbuttonbypressing thebuttonandrotatetomaximumbeingcarefulto avoidscalding Measurethetemperature 4 Thevalveshouldthenbecheckedtoconfirmthe waterisolationperformscorrectly...

Page 14: ...evalveandcleanfilters 4 Showerheadblocked CleanShowerhead 5 Systemnotcapableofsupplyingmultipleoutlet atthesametime Reducesimultaneousdemand Checkstop servicevalvesarefullyopen Checkifenough waterpres...

Page 15: ...toyouthecustomer 2 Thisguaranteeispersonaltotheoriginalpurchaserofthe productandisnottransferable 3 Originalproofofpurchase s mustbeshownforanyclaim underthisguarantee 4 Thisguaranteedoesnotcoveranypr...

Page 16: ...upplied 6 Servicechargesarebasedontheaccountbeing settledwhenworkiscomplete theengineerwill thenrequestpayment Ifthisisnotmadetothe serviceengineerorsettledwithintenworkingdays anadministrationchargew...

Reviews: