background image

13

What is not covered by this guarantee:

1.  

 Any product found to be defective during this period, as the result of misuse or damage, 

or the effects of scaling, will not be covered by this guarantee.

2.  

Breakdown due to:

• 

Use other than domestic use by you or your resident family

• 

Wilful act or neglect

• 

Any malfunction resulting from the incorrect use or quality of water or incorrect 

setting of controls; and

• 

Faulty installation.

3. 

 Repair costs for damage caused by foreign objects of substances or the inappropriate 

use of jointing compounds or blow torches.

4.  

 Total loss of the product due to non-availability of parts or other reason, (MX Group will 

maintain stocks of spare parts for repair for at least 5 years from end of product line to 

cover this guarantee).

5.  

Compensations for loss of use of the product or consequential loss of any kind.

6.  

Call out charges where no fault has been found with the appliance.

7.  

 The cost of repair or replacement of pressure relief devices, showerheads, hoses,  

riser rails and/or wall bracket, tiles, cubicles or any other parts installed at the same time.

8.  

 The cost of routine maintenance, adjustments, overhaul modifications or loss or damage 

arising there from, including the cost of repairing damage, breakdown, malfunction 

caused by corrosion, furring, pipe scaling, limescale, system debris or frost.

9.  

Units purchased and installed other than in the United Kingdom.

LIMITATIONS

1.  

 This guarantee lasts for a single continuous period of 5 years from the date of delivery 

by MX Group to you the customer.

2.  

 This guarantee is personal to the original purchaser of the product and is not transferable.

3.  

Original proof of purchase(s) must be shown for any claim under this guarantee.

4.  

 This guarantee does not cover any products that have been modified, altered or 

transformed in any way.

5.  

 This guarantee applies to an original installation in accordance to our fitting instructions 

and does not cover previously installed products (showroom displays etc) or products 

that have been moved from their original installation position for any reason.

6.  

 This guarantee applies only to manufacturing or material defects. It does not apply to 

normal wear and tear, accidental damage, inappropriate use (including inappropriate 

cleaning) or other events outside the manufacturer’s control.

MX Atmos Select 6752B 09_14_GF.indd   14

24/10/2014   14:57

Summary of Contents for Atmos Select Round

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS Atmos Select 3 Way Thermostatic Concentric Mixer Valve with Riser Rail Overhead Customer Care 0845 505 2211 MX Atmos Select 6752B 09_14_GF indd 1 24 10 2014 14 56 ...

Page 2: ...r temperature to a minimum of 52 C The water temperature at the inlet to the mixer valve must remain relatively constant when flow rate adjustments are made refer to the water heater operating manual to confirm compatibility with this mixer shower Inlet connections are female BSP threads which can be connected to 15mm or 22mm compression fittings not included SAFETY WARNINGS Layout and sizing of p...

Page 3: ...ewateratapointnotlessthan25mmabovethe spill over level of the relevant bath shower tray or other fixed appliance A double check valve or similar MUST be fitted in the supply pipework to prevent back flow The pressure at both the hot and cold water supplies to the mixer valve should be the same and the installer should ensure that the flow is not affected by other taps elsewhere in the house It is ...

Page 4: ...mixer valve is designed to work at the same hot and cold water pressures If this is not the case a flow controller disc with small holes can be fitted to the higher pressure supply to the valve This is best done by testing each one to find out which gives the best results Remember the mixer valve must installed in such a position that the maintenance of the TMV and the filters can be done after in...

Page 5: ...s stated on the valve SITING OF THE SHOWER Having established the position of the mixer valve so that all controls can be comfortably reached whilst using the shower the handset and riser rail should be positioned at the side of the valve and the overhead rail directly above the valve Make sure any cables and pipework are not behind the required screw holes Consult the illustration below to make s...

Page 6: ...mm and 110mm should be large enough to fit the mixer valve The valve should be fixed to the wall between 75mm and 90mm below the finished surface of the shower See Fig 5 2 The supply pipework can be plumbed from above or below but must finish at the suitable connections which should be at approximately 150mm centers See Fig 6 provision should be made for some adjustment on fitting the valve 3 Fit ...

Page 7: ...These pipes must end in female connection so the wall outlet and overhead arm can be fitted If fitting as a 2 way valve the unused outlet must be blanked off using the BSP blank plug supplied 9 Once the mixer valve and wall outlet are fitted prior to fitting the trim plate ensure all connections are watertight This can be done by reconnecting the water supplies and check all connections To do this...

Page 8: ...See Fig 12a b RISER RAIL FITTING FOR Square Style 1 Having established the position of the riser rail so that the showerhead can be comfortably reached whilst using the shower make sure any cables and pipework are not behind the screw holes See Fig 1 2 Remove caps and covers from brackets See Fig 2 3 For new installation Drill plug and screw For replacement installation locate bottom hole and scre...

Page 9: ...les and pipework are not behind the screw holes See Fig 6 2 Remove end bracket cover to explore fitting point from upper of lower brackets See Fig 7 3 Drill and plug the wall and fix the lower bracket without the rail locator notch Fit rail to lower bracket Place the remaining bracket on top of the rail making sure the slot in the rail is located into the bracket notch Ensure the hole position is ...

Page 10: ...without the double interlock hose attached WALL ARM FITTING 1 Establish position of wall arm to suit users requirements See Fig 12 2 When fitting the wall arm drill a suitable 19mm hole through the wall you may require a suitable piece of wood to give the arm support behind the tiles or plasterboard 3 Remove fittings and nuts from end of arm and push arm through wall re fit washer and nut 4 Connec...

Page 11: ... isolation valve The water flow should fall to a very low flow possibly only a drip after a few seconds Collect the water after 5 seconds and 30 seconds and measure the temperature it should be below 46 C 2 C Turn on the cold water again and it should return after a few seconds to stabilise to 38 C 2 C Ensure that you instruct all users in the safe operation of the shower as outlined in this docum...

Page 12: ...tlet at the same time A Running pressure in excess of maximum recommended A Flow control cartridge worn SUGGESTED ACTION Remove valve and clean filters Adjust temperature control Turn the temperature control anti clockwise Turn the temperature control anti clockwise Remove valve and clean filters on the inlet Make sure the hot water is available by trying a hot water tap elsewhere in the house Tur...

Page 13: ...stration Card 1 Flow Controller 2 MX GROUP GUARANTEE Marleton Cross Limited and its subsidiaries MX Group hope you are satisfied with your purchase and in the unlikely event that you encounter a problem which is caused exclusively by MX Group manufactured product the product we will take responsibility on the terms set out here We guarantee this product in the following terms for a period of 5 yea...

Page 14: ...installed at the same time 8 Thecostofroutinemaintenance adjustments overhaulmodificationsorlossordamage arising there from including the cost of repairing damage breakdown malfunction caused by corrosion furring pipe scaling limescale system debris or frost 9 Units purchased and installed other than in the United Kingdom LIMITATIONS 1 This guarantee lasts for a single continuous period of 5 years...

Page 15: ...s damage or injury suffered or incurred by you and you will indemnify us fully against any claims made by third parties in respect of the goods or otherwise arising from the contract 3 Nothing contained in the contract will be treated as excluding or restricting any liability on our part for death or personal injury resulting from our negligence 4 Except as stated above and to the fullest extent p...

Page 16: ...it The engineer will not be able to repair or replace or advise on parts or products not supplied as part of the product 4 A charge will be made in the event of a service call aborted by you but not by us or where a call under the terms of guarantee has been booked and failure is not related to product supplied by MX Group i e Scaling and furring incorrect water pressure or other plumbing problem ...

Reviews: