6 / 14
BETA series
Model:
BETA 12K WIFI
BETA-installation-manual-EN-R1 27.07.2020
After having connected the pipe according to the instructions,
install the connection cables. Now install the drain pipe. After
connection, lag the pipe, cables and drain pipe with the insulating
material.
1.
Arrange the pipes, cables and drain hose well.
2.
Lag the pipe joints with insulating material, securing it
with vinyl tape.
3.
Run the bound pipe, cables and drain pipe through the
wall hole and mount the indoor unit onto the upper part
of the mounting plate securely.
4.
Press and push the lower part of the indoor unit thightly
against the mounting plate.
3.
I
NSTALLATION OF THE OUTOOR UNIT
•
The outdoor unit should be installed on a solid wall and fastened securely.
•
The fallowing procedure must be observed before connecring the pipes and connecring cavles:
decide which is the best position on the wall and leave enough space to be able to carry out
maintenance easily.
•
Fasten the support to the wall using screw anchors which are particularly suited to the type of
wall.
•
Use a larger quantity of screw anchors the normally rquired for the weight they have to bear to
avoid vibration during operation and remain fastened in the same position for years without the
screws becoming loose.
•
The unit must be installed following the national regulations.
3.1.
O
UTDOOR UNIT CONDENSED WATER DRAINAGE
(
ONLY FOR HEAT PUMP MODELS
)
The condensed water and the ice formed in the outood unit during
heating operation can be drained away through the drain pipe.
1.
Fasten the drain port in the 25mm hole placed in the part
of the unit as shown in the picture.
2.
Connect the drain port and the drain pipe. Pay attention
that water is drained in a suitable place.
3.2.
E
LECTRICAL CONNECTIONS
1.
Remove the handle on the right side plate of outdoor unit.
2.
Connect the power connection cord to the terminal board.
Wiring should fit that of indoor unit.
3.
Fix the power connection cord with wire clamp.
4.
Confirm if the wire has been fixed properly.
5.
An efficient earth connection must be ensured.