4
POD40 - POD60 - NLFREN - v1.0 - 25032017
EN
TOOLS
1 Safety instructions
•
The power source voltage should be confirmed to match the power input of the pump prior to connecting to the pump.
• Voltage tolerance of +- 5%.
• Oil transfer is in the direction of the arrow as indicated on the pump.
•
Be sure to have an air-tight seal on the suction hose so proper flow can be achieved. The filter screen should be installed on
the end of the suction hose to prevent debris from damaging the pump.
• The duty cycle of this pump is 30 minutes under normal usage. The pump has thermal protection and may shut off if the
maximum operating temperature of the pump is achieved.
Note:
Not suitable for low ignition fuel (such as gasoline, LPG, alcohol, etc.) transmission.
2 Technical parameters
Model
POD40
POD60
Pump flow rate
20 - 40 l/min
20 - 60 l/min
Meter flow rate
20 - 120 l/min
20 - 120 l/min
Voltage
DC 12 V
DC 24 V
AC 220 V 50 HZ
AC 220 V + 10%
50 Hz / 60 Hz
Maximum working pressure
3 bar
Meter accuracy
+ 1%
Motor parameter
Power: 0.15 kW
Power: 0.375 kW
Turn speed: 2800 rpm
In - Out
In BSP 3/4’’
Out BSP 3/4’’
In BSP 1’’
Out BSP 1’’
Digit
4 digit, max. 999.9 liter, 8 digit accumulated
Temperature
-25 °C - +55 °C
Relative humidity
30% - 90%
High atmospheric pressure
86 kPa - 106 kPa
3 Troubleshooting
Troubles
Possible reasons
Solutions
No initial oil output
Polarity reversed (+/-)
Correctly attach polarity to power /-
Leak in suction line
Ensure the suction hose is securely fastened and there
are no leaks
Pump not primed
Prime the pump by adding oil to near the pump inlet
Little oil flow
Low voltage supply
Increase the supply voltage to proper levels
Excessive suction height or head
Reduce suction height or head
Obstruction in the filter strainer
Clear foreign objects, clean filter strainer
Vanes worn or gear broken
Replace the vanes or gear