When communicating with factory about a unit or requesting for special parts or information, 
Rating plate data is essential for proper identification. 

SIERRA COOKING APPLIANCES MUST BE CONNECTED ONLY TO THE TYPE OF GAS 

TROUBLE
SHOOTIN

BURNER AND/OR PILOTS NOT 
TURN ON 

GAS SUPPLY TO COOKING 
EQUIPMENT IS OFF 

TURN ON GAS SUPPLY 

UNIT PRODUCING CARBON 
DEPOSITS 

GAS TYPE 

VERIFY CORRECT GAS 

GAS SUPPLY PRESURE 

CONTACT LOCAL GAS SUPPLIER 

PRIMARY AIR NOT ADJUSTED 
PROPERLY 

ADJUST AIR SHUTTER 

ORIFICE TOO BIG 

VERIFY ORIFICE SIZE 

PILOT WILL NOT REMAIN LIT 

PILOT FLAME NOT ADJUSTED 

ADJUST PILOT FLAME 

DRAFT CURRENTS NEAR 
EQUIPMENT 

FIX DRAFT 

NOT ENOUGH VENTILATION 

CONTACT HVAC CONTRACTOR 

DEBRIS OR GREASE CLOGGING 
PILOT BURNER 

CLEAN DEBRIS AND GREASE 
FROM PILOT BURNER 

EXCESSIVE FLARE-UP 

OVERLOAD OF OIL AND 
LEFTOVERS  

CLEAN AND PREPARE PAN 

NOT HEATING PROPERLY 

ORIFICES DIRTY/CLOGGED 

CLEAN ORIFICE, MAKE SURE 
THERE IS NO RESTRICTION IN THE 
ORIFICE BURNER 

LOW GAS PRESSURE 

INCREASE GAS PRESSURE TO 5” 
WC (NAT) OR 10” WC (L.P.)

 

GRATES DIRTY/CLOGGED 

CHECK AND CLEAN TOP GRATES 

IF THE VENTILATION IS TO 
STRONG IT WILL DRAFT HEAT 
FROM THE COOKING/BROILING 
SURFACE 

CALL HVAC CONTRACTOR 

Summary of Contents for Sierra SRMG-12

Page 1: ...RMG 24 SRMG 36 SRMG 48 SRMG 60 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE 108 MIAMI FL 33181 TEL 786 600 4687 1 844 218 8477 sales mvpgroupcorp com www mvpgroupcorp com ...

Page 2: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les in...

Page 3: ...f converting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspec...

Page 4: ...ed to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit OPERATING INSTRUCTIONS Before lighting check all joints in the gas supply line for leaks DO NOT USE OPEN FLAME TO CHECK FOR LEAKS USE SOAP AND WATER SOLUTION Putt...

Page 5: ...DAILY Clean top grate s with warm water mild cleaner and wire brush Clean and brush off debris from and around the burner area Empty and clean grease pan Griddle plates should be cleaned with warm water and scrubbed with cleaning abrasive such as a griddle brick of fine grit type Top surface can also be bleached with vinegar pickle juice or club soda when the plate is warm to give the plate a new ...

Page 6: ...ution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas supplier or the appliance manufacturer for complete instructions MANUAL SHUT OFF VALVE This installer sup...

Page 7: ... Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inches AIR SUPPLY VENTILATION The area in front of around and above the appliance must be kept clear to avoid any obstruction of the flow of combustion and ventilation air Adequate clearance must be maintained around the appliance for easy servicing Provision should be made for any commercial heavy duty cooking appliance exhaust combustion waste prod...

Page 8: ... SHUTTER ORIFICE TOO BIG VERIFY ORIFICE SIZE PILOT WILL NOT REMAIN LIT PILOT FLAME NOT ADJUSTED ADJUST PILOT FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CL...

Page 9: ...ierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional ...

Page 10: ...0 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canadá H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...