Provisions  shall  be  incorporated  in  the  design  of  the  kitchen,  to  ensure  adequate  supply  of  fresh  air  and 
adequate clearance for air openings into the combustion chamber, for proper combustion, and ventilation. For 
proper operation of the appliance, do not obstruct the flow of combustion and ventilation air. 

The installation must conform with local codes, or in the absence of local codes, to the national fuel gas code, 
ANSI Z223.1 (or latest addenda). The Appliance and its individual shut off valve must be disconnected from the 
gas supply piping system during any pressure testing of that system in excess of ½ PSI (3.45Kpa). 

The  appliance  must  be  isolated  from  the  gas  supply  piping  system  by  closing  its  individual  manual  shut  off 
valve during any pressure testing of the gas supply piping system at test pressures equal to or less than ½ PSI 
(3.45Kpa). 

The gas supply line must be at least the same size as the gas inlet of the appliance. 

FLEXIBLE COUPLINGS, CONNECTORS AND CASTERS 

For an appliance equipped with casters the installation shall be made with a connector that complies with the 
Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 or Connectors for Moveable Gas Appliances, 
CAN/CGA-6.16, and a quick 

disconnect device that complies with the standard for Quick Disconnect Devices for Use with Gas Fuel, ANSI

Z21.41, or Quick Disconnect  Devices for Use  with Gas Fuel, CANI-6.9. Adequate means must  be  provided to
limit the movement of the appliance without depending on the connector and the quick-disconnect device or
its associated piping to limit the appliance movement.
Restraining devices may be attached to the back frame/panel of the unit.

OPERATING INSTRUCTIONS

: Before lighting, check all joints in the gas supply line for leaks. 

DO NOT USE OPEN 

FLAME TO CHECK FOR LEAKS! USE SOAP AND WATER SOLUTION. 

Putting an open flame beside a new gas connection is extremely dangerous. 
LIGHTING Initial pilot lighting: 
CAUTION: When lighting pilots  and checking for leaks, do not  Stand with your face  close to the combustion 
chamber. 
All Sierra appliances are adjusted and tested before leaving the factory, effectively matching them to sea level 
conditions. Adjustments and calibrations to assure proper operation may be necessary on installation to meet 
local conditions; low  gas characteristics,  to correct  possible problems caused by rough handling or vibration 
during  shipment,  and  are  to  be  performed  only  by  qualified  service  personnel.  These  adjustments  are  the 
responsibility of the customer and/or dealer and are not covered by our warranty. Before lighting any pilots, 

make sure that burner valves and thermostats are turned “off”.

 

A. TOP BURNERS / RAISED GRIDDLE

BROILER / BROILER

. All top section burners are equipped with constant

burning  pilots.  These  are  to  be  manually  lighted  immediately  after  the  gas  is  turned  on  and  the  system  is
checked  for  leaks.  Burner pilots  are  provided  for each  burner  and  can  be  rechecked  for  proper  adjustment.
Adjustments can be made with a screwdriver to
the brass pilot valve accessible through the valve cover.

Summary of Contents for Sierra SRMG-12

Page 1: ...RMG 24 SRMG 36 SRMG 48 SRMG 60 READ THIS MANUAL IN IT S ENTIRELY BEFORE USING THIS EQUIPMENT 5659 ROYALMOUNT AVE MONTREAL QC CANADA H4P 2P9 TEL 514 737 9701 1 888 275 4538 12000 BISCAYNE BLVD STE 108 MIAMI FL 33181 TEL 786 600 4687 1 844 218 8477 sales mvpgroupcorp com www mvpgroupcorp com ...

Page 2: ...ation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment MISE EN GARDE Une installation un réglege une modification ine réparation ou un entretien inadécuat peut provoquer des dommager matériels des blessures ou la mort Lisez sougneusement les in...

Page 3: ...f converting the gas appliance from natural to propane or vice versa all orifices and the regulator must be changed The correct type of gas for which the unit is configured is noted on the name plate The type of gas specified MUST be used For proper conversion contact a qualified service technician or your Factory Authorized Service Center SHIPPING DAMAGE CLAIM PROCEDURE Merchandise must be inspec...

Page 4: ...ed to limit the movement of the appliance without depending on the connector and the quick disconnect device or its associated piping to limit the appliance movement Restraining devices may be attached to the back frame panel of the unit OPERATING INSTRUCTIONS Before lighting check all joints in the gas supply line for leaks DO NOT USE OPEN FLAME TO CHECK FOR LEAKS USE SOAP AND WATER SOLUTION Putt...

Page 5: ...DAILY Clean top grate s with warm water mild cleaner and wire brush Clean and brush off debris from and around the burner area Empty and clean grease pan Griddle plates should be cleaned with warm water and scrubbed with cleaning abrasive such as a griddle brick of fine grit type Top surface can also be bleached with vinegar pickle juice or club soda when the plate is warm to give the plate a new ...

Page 6: ...ution before lighting any pilots The appliance shall be connected to the fuel gas for which it was designed No attempt shall be made to convert the appliance from the gas specified on the rating plate for use with a different gas without consulting the installation instructions the serving gas supplier or the appliance manufacturer for complete instructions MANUAL SHUT OFF VALVE This installer sup...

Page 7: ... Inches REAR 8 Inches 0 Inches FLOOR 6 Inches 0 Inches AIR SUPPLY VENTILATION The area in front of around and above the appliance must be kept clear to avoid any obstruction of the flow of combustion and ventilation air Adequate clearance must be maintained around the appliance for easy servicing Provision should be made for any commercial heavy duty cooking appliance exhaust combustion waste prod...

Page 8: ... SHUTTER ORIFICE TOO BIG VERIFY ORIFICE SIZE PILOT WILL NOT REMAIN LIT PILOT FLAME NOT ADJUSTED ADJUST PILOT FLAME DRAFT CURRENTS NEAR EQUIPMENT FIX DRAFT NOT ENOUGH VENTILATION CONTACT HVAC CONTRACTOR DEBRIS OR GREASE CLOGGING PILOT BURNER CLEAN DEBRIS AND GREASE FROM PILOT BURNER EXCESSIVE FLARE UP OVERLOAD OF OIL AND LEFTOVERS CLEAN AND PREPARE PAN NOT HEATING PROPERLY ORIFICES DIRTY CLOGGED CL...

Page 9: ...ierra hereby states that warranty travel time shall be limited to and without exception a round trip total of two 2 hours OR mileage up to a maximum of one hundred fifty 150 kilometers round trip Any charges exceeding those stated herein must have prior authorization by the factory A special warranty covers the SRF series These units carry the regular one 1 year parts and labor plus an additional ...

Page 10: ...0 514 737 9701 888 275 4538 service mvpgroupcorp com 5659 Royalmount Ave Montreal QC Canadá H4P 2P9 786 600 4687 844 218 8477 service mvpgroupcorp com 12000 Biscayne Blvd Suite 108 Miami FL United States 33181 ...

Reviews: