MV Heating UK Ltd
The fuel pump’s outlet should tilt upward at an
angle between
15˚
-
35˚ (as shown above).
Only use the fuel line provided, ensure the pipe is
placed away from any possible debris and avoid any sagging in the line. Make
sure the fuel line does not flow downward toward the fuel pump. This will
prevent correct fuel flow and produce air bubbles in the line.
The fuel filter, fuel pipe and clamps should all be replaced after 2 years of us
1
2
Correct
Wrong
1.
Flush
–
No Air Bubble
2.
Gap
–
Air Bubble Formed
Figure XIX
Figure XIX shows the correct way to connect fuel lines to prevent the build-up
of air bubbles. Ensuring they are flush and minimising bends.
When the fuel is being sucked from the vehicle tank, or an independent tank,
a suction pipe is required. Make sure all the openings are appropriate for the
installation and a tight seal is maintained for the base of the suction pipe.
The bottom of the suction pipe should be about 30-40mm from the bottom of
the fuel tank so as to avoid sucking impurities or sediment from the bottom
of the fuel tank.