Symptom

Probable Causes

Possible Solutions

No continuity in video link

Verify cable continuity between baluns.

Power off

Check power supplies of VGA equipment.

No video

PC settings

Perform diagnostics on your VGA equipment
by following the manufacturer’s instructions.

Image distorted or skewed.

Specific display unable to sync
up

Follow RESET procedure in manual to force
display to sync up correctly.

Image not stable

Defective link or equipment

Verify VGA equipment interface integrity.

Unusual colors

Reversed polarity

Ensure wiring is straight-through polarity.

Background pattern

EMI interference

Identify possible radiating frequency sources
Try to isolate them from the video. Use
shielded twisted pair grounded at both ends.

Smearing

Exceeded distance

Verify cable grade. Use higher grade cable.

Exceeded distance

Verify cable grade. Use higher grade cable if
necessary. Adjust contrast on monitor.

Weak contrast

Unusual link attenuation

Verify cable distance using cable tester.

Horizontal bars moving upward
in background

Ground loop problem

Assure that PC and Monitor are connected to
the same ground. Disconnect PC or monitor
from the ground.

1 to 2 pixel object random
dislocation

High noise level in the room.
Distance exceeded.

Set another resolution and refresh rate.
Review connectivity.

Slight variance in hue between
left and right display margins

Slight background noise

Connect ground terminal to earth ground.

Shaking image

Possible ground loop problem

Disconnect gnd terminal from earth ground.

If  you  still  cannot  diagnose  the  problem,  please  call  MuxLab  Customer  Technical
Support  at  877-689-5228  (toll-free  in  North  America)  or  (+1)  514-905-0588
(International).