VJ-1614 INSTALLATION MANUAL
VJ1614E-I-00
4
1
2
2
1
1
1
1
2
1
2
1
g
e
a
d
b
c
f
1
2
4.1.2 Installation space
Install on a level floor which meets the following condition.
It has enough strength to support the weight of the
printer and the stand.
For the weight of the printer and the stand, refer to
the Operation Manual.
a = 650 mm
b = 1,000 mm
e = 1,550 mm
c = 1,000 mm
f = 3,800 mm
d = 1,000 mm
g = 2,700 mm
4.2 Installation procedure
Install this product to the installation place in accord-
ance with the list shown below.
1. Carry the printer to the installation place.
2. Turn the following adjusters in the direction as
shown below to prevent the printer from moving.
Stands: adjusters (4)
3. Set the spirit level on the right and left platens and
adjust so that the printer stays flat.
4. Confirm that the waste fluid valve is closed.
5 Connecting the power cable
This section explains how to connect the power cable.
Make sure that the included power ca-
ble is used.
If other power cables are used, it may
cause an electric shock or fire.
Do not use a damaged power cable. It
may cause an electric shock or fire.
Follow the steps below to connect the power cable.
1. Confirm that the product is turned OFF.
If the [Power] key is pressed, the product is turned
ON. Press the key again, and turn OFF the power.
2. Connect the power cables (x 2) to the AC inlets (x 2)
on the right of the product.
3. Correctly insert the power cable plug into the power
socket.
To use the two power cables plugged in the inlets,
a total capacity of 17 A or over is required. If the
power source cannot supply the required capacity,
plug the two power cables in the different power
sources respectively.
NOTE
4 Installation
Procedures and environment for installing this product
are explained.
4.1 Installation environment
Install this product to the appropriate place with refer-
ence to the following.
Do not install the printer in the follow-
ing places where there is a possibility
that the printer may be damaged or
might fall or be fallen by chance.
On a shaky stand
Slanting location
Places where vibration of other machines
etc. is transmitted.
Do not stamp on the printer or do not
place heavy things on top of it. The
printer may be damaged or might fall
or be fallen by chance.
Cover the printer with blanket and cloth
like tablecloth and do not close the vent.
If the vent is closed, the printer could
accumulate heat inside and may cause
fire.
Do not install the printer in a location
that has high humidity or is dusty.
It could lead to electric shock and fire.
4.1.1 Installation environmental condition
Select an installation location in accordance with the
table below.
For temperature and humidity, avoid locations
such as the following. There is a possibility that
the print quality will be affected.
Places where temperature or humidity may
rapidly change, even though within the required
conditions.
Places that receive direct sunlight, increased illu-
mination or direct air, for example from an air
conditioner.
To keep the temperature and humidity constant, in-
stall this product in a location where the air condi-
tion is adjustable.
No.
Name
1
Adjuster
No.
Name
2
Stand
No.
Name
1
Waste fluid valve
No.
Name
1
AC inlet
No.
Name
2
Power cable
No.
Name
1
Power cable
No.
Name
1
Spirit level
No.
Name
2
Adjuster
More than 2940 Pa (300 kg/m
2
)
Power
Specifica-
tion
Environm-
ental
conditions
Floor strength of
installation place
Power
Supply
Frequency
Range
AC 90 V to 132 V / 198 V to 264 V
50/60Hz ± 1Hz
Power
capacity
Change
rate
Operative
condition
Archiving
environment
Guaranteed
range of
printing
accuracy
Main: 8.5 A / 4.5 A
Heater: 8.5 A / 4.5 A
Temperature: 20 °C to 32 °C
Humidity: 40 % to 60 %, No Condensation
Temperature: 22 °C to 30°C
Humidity: 40 % to 60 %
Temperature: within 2 °C per hour
Humidity: within 5 % per hour
Temperature: -20° C to 60 °C
Humidity: 20 % to 80 % ,
No Condensation (Ink unfilled)
WARNING
NOTE
NOTE
WARNING
NOTE