Selecting Function Areas and setting Functions
The device is fully operated using the two toggle switches at the front
panel.
1 Switching the SELECT switch selects between different basic
function areas.
2 Switching the DATA switch selects between the individual
functions within one function area.
For safety reasons, be sure to read
the SAFETY INSTRUCTIONS and
INSTALLATION chapters before first
powering-up!
We also recommend reading the CONTROLS
AND TERMINALS chapter for information on
how to connect MC-2!
!
Steps of Operation
1 First press on SELECT or DATA switch enables the last selected function
within the last selected function area. The corresponding LED is
beginning to flash.
2 Every press on DATA switch will select a new function. The LED of every
selected function will flash accordingly and the corresponding function is
available at once.
3 When the needed function is selected, do not press the switches again!
After a period of approx. 4 seconds the LED in front of the selected
function will stop flashing.
The STATUS area is not accessible by using the SELECT and DATA switches,
because it only informs about different conditions of incoming digital
audio signals.
All user-specific function settings
are available furthermore when
power is restored.
!
Functions
Functions
Function Areas + Status Areas
Function
Areas
Status Areas
DATA operation
2. DATA
selects individual
functions within
one function
area.
1. SELECT
selects individual
function areas.