17
ENGLISH
Malfunction: amplifier runs into protection mode
Reason:
Remedy:
1. Short circuit on the loudspeakers or cables
Reconnect
2. Overheated by too low speaker impedance
Choose a higher impedance
Use a new speaker setup
3. Insufficient air circulation by a inappropriate mounting position of the amplifier
Change the mounting position
Ensure air circulation
4. Overloaded by insufficient power supply (too small profile section on the power cables)
Use a bigger profile section
Malfunction: hiss or white noise on the loudspeakers
Reason: Remedy:
1. The level controllers in the DSP software are turned up to loud
Turn down the level
2. The treble controller on the head unit is turned up
Turn down the level on the head unit
3. The speaker cables or the RCA audio cables are defective
Replacing the cables
4. The hissing is caused by the head unit
Check the head unit
Summary of Contents for D8v2