background image

 

24

6. Specifications 

 

MODEL 

PowerMust 6048 

Online LCD X

 

PowerMust 6048 

Online LCD X

L

 

PowerMust 

10800 Online 

LCD X

 

PowerMust 

10800 Online 

LCD X

L

 

CAPACITY* 

6000 VA / 4800 W 

10000 VA / 8000 W 

INPUT 

Input Voltage Range 

110 ~300 VAC at 50% Load;   

176~300 VACat 100% Load 

Frequency Range 

46Hz ~ 54 Hz or 56Hz ~ 64 Hz 

Phase 

Single phase with ground 

Power Factor 

 0.99 at 100% Load 

OUTPUT 
Output voltage 

208/220/230/240VAC 

AC Voltage Regulation   

± 1% 

Frequency Range   
(Synchronized Range) 

46Hz ~ 54 Hz or 56Hz ~ 64 Hz 

Frequency Range (Batt. Mode) 

50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz 

Current Crest Ratio 

3:1 max 

Harmonic Distortion 

 3 % THD (Linear Load), 

 6 % THD (Non-linear Load) 

Transfer Time 

Line

Battery 

0 ms 

Inverter

Bypass 

0 ms 

EFFICIENCY 
Line Mode 

89% 

90% 

Battery Mode 

88% 

89% 

BATTERY 

Standard 
Model 

Type & Numbers 

12 V / 9 Ah x 16 

12 V / 9 Ah x 20 

Recharge Time 

9 hours recover to 90% capacity 

9 hours recover to 90% capacity 

Charging Current   

Default : 1 A ± 10% 

Max.: 2A ± 10% 

Charging Voltage   

218.4 VDC ± 1%   

273 VDC ± 1% 

Long-run 
Model 

Type 

Depending on applications 

Numbers 

16 – 20 (adjustable) 

Note: 

When using internal batteries from 16 to 19, the unit will de-rate according to the 

following formula: P = P

Rating

 x N/20.

 

Charging Current   

Default: 4 A ± 10%           

Max.: 6A ± 10% 

Charging Voltage 

273 VDC ± 1% (based on 20pcs batteries) 

PHYSICAL 

Standard 
Model 

Dimension,DXWXH(m
m) 

369 x 190 x 688 

442x 190 x 688 

Net Weight (kgs) 

60 

75 

Long-run 
Model 

Dimension, 
DXWXH(mm) 

369 x 190 x 318 

442x 190 x 318 

Net Weight (kgs) 

21 

23 

ENVIRONMENT 
Operation Humidity 

<95 % and non-condensing 

Noise Level 

Less than 55dB @ 1 Meter 

Less than 58dB @ 1 Meter 

MANAGEMENT 
Smart RS-232 or USB 

Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC 

Optional SNMP 

Power management from SNMP manager and web browser 

* Derate capacity to 60% of capacity in CVCF mode and to 90% when the output voltage is adjusted to 208VAC. 
**If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m. 
***Product specifications are subject to change without further notice. 

Summary of Contents for POWERMUST 10800 ONLINE LCD

Page 1: ...PowerMust 6048 Online LCD X PowerMust 10800 Online LCD X Uninterruptible Power Supply System User Manual EN...

Page 2: ...g instructions in this manual strictly Save this manual properly and read carefully the following instructions before installing the unit Do not operate this unit before reading through all safety inf...

Page 3: ...W 5 2 3 SINGLE UPS INSTALLATION 6 2 4 SOFTWARE INSTALLATION 8 3 OPERATIONS 9 3 1 BUTTON OPERATION 9 3 2 LED INDICATORS AND LCD PANEL 9 3 3 AUDIBLE ALARM 11 3 4 SINGLE UPS OPERATION 11 3 5 ABBREVIATION...

Page 4: ...nect appliances or devices which would overload the UPS e g big motor type equipment to the UPS output sockets or terminal Place cables in such a way that no one can step on or trip over them Do not b...

Page 5: ...mains Ensure that no liquid or other foreign objects can enter into the UPS system The UPS can be operated by any individuals with no previous experience 1 5 Standards Safety IEC EN 62040 1 EMI Condu...

Page 6: ...npack the package and check the package contents The shipping package contains One UPS One user manual One monitoring software CD One RS 232 cable option One USB cable One battery cable option NOTE Be...

Page 7: ...g must be performed in accordance with the local electric laws regulations and execute the following instructions by professional personnel 1 Make sure the mains wire and breakers in the building are...

Page 8: ...making wire connection Disconnect the earth wire last when making wire disconnection Terminal Block wiring diagram for 6K L 10K L NOTE 1 Make sure that the wires are connected tightly with the termin...

Page 9: ...battery pack please make sure you modify the setting simultaneously The connection with wrong battery voltage may cause permanent damage of the UPS Make sure the voltage of the battery pack is correc...

Page 10: ...this button to display next selection in setting menu Mute Down Button Mute the alarm Press and hold the button more than 0 5s to mute the buzzer Please refer to section 3 4 9 for details Down key Pr...

Page 11: ...s disabled Output Battery voltage information Indicates the output voltage frequency or battery voltage Vac output voltage Vdc battery voltage Hz frequency Load information Indicates the load level by...

Page 12: ...an failure Over temperature Charger failure IP fuse broken Overload 3 times in 30min EPO status Cover of maintain switch is open Fault Bus start failure Beeping continuously Yes Bus over Bus under Bus...

Page 13: ...please remove some loads immediately It is recommended to have the total loads connected to the UPS less than 80 of its nominal power capacity to prevent overload for system safety 5 If the overload...

Page 14: ...output sockets and terminal even though you have turned off the UPS inverter NOTE 2 After turning off the UPS please be aware that the UPS is working at Bypass mode and there is risk of power loss for...

Page 15: ...e for long run model or disconnect battery wire for standard model 4 Remove the cabinet cover and then modify the jumpers JP1 JS3 on the control board to set the battery numbers as following table Bat...

Page 16: ...Reserved 08 Bypass mode setting Y Y 09 Battery maximum discharge time setting Y Y Y Y Y 10 Reserved 11 Reserved 12 Reserved 13 Battery voltage Calibration Y Y Y Y Y 14 Charger voltage adjustment Y Y Y...

Page 17: ...he input frequency within 46 54 Hz at 50Hz or within 56 64 Hz at 60Hz according to setting in parameter 2 If 50 Hz selected in parameter 2 UPS will transfer to battery mode when input frequency is not...

Page 18: ...e is activated DIS Bypass disabled When selected automatic bypass is acceptable but manual bypass is not allowed Manual bypass means users manually operate UPS for Bypass mode For example pressing OFF...

Page 19: ...ltage range is from 0V to 5 7V the default value is 0V 14 Charger voltage adjustment Interface Setting Parameter 2 you may choose Add or Sub to adjust charger voltage Parameter 3 the voltage range is...

Page 20: ...4A automatically even though the setting is 6A 19 Battery capacity and groups setting Interface Setting Parameter 2 Set the battery capacity such as 7AH 9AH 10AH 12AH 17AH 26AH 40AH 65AH 100AH and so...

Page 21: ...splay Battery mode Description When the input voltage is beyond the acceptable range or power failure UPS will backup power from battery and alarm will beep every 4 seconds LCD display Bypass mode Des...

Page 22: ...lay short circuited 24 None Inverter soft start failure 11 None Over temperature 41 None High Inverter voltage 12 None CPU communication failure 42 None Low Inverter voltage 13 None Overload 43 3 9 Wa...

Page 23: ...is locked in the Bypass mode Connected devices are fed directly by the mains Remove excess loads from UPS output first Then shut down the UPS and restart it Fault code is shown as 43 The icon lights...

Page 24: ...required precautionary measures may replace batteries and supervise operations Unauthorized persons must be kept well away from the batteries Verify that no voltage between the battery terminals and...

Page 25: ...2A 10 Charging Voltage 218 4 VDC 1 273 VDC 1 Long run Model Type Depending on applications Numbers 16 20 adjustable Note When using internal batteries from 16 to 19 the unit will de rate according to...

Reviews: