Müssel ASG 1000 Operating Instructions Manual Download Page 8

 

Operating instruction: B013          Edition: 01/2015 

 

Subject to alterations.

 

8

Never  make  any  modifications,  additions  or  conversions  which  might  affect  safety  without  the 
supplier´s approval. 
Additional  mountings  or  modifications  have  as  consequence  that  the  responsibility  for  the 
accordance with the EU-directive has to be assured by the person who carries out the mountings 
and the modifications. 
Spare parts, only from the original equipment, comply with the technical requirements specified by 
the manufacturer and guarantee the failure-free operation of the device.  
 

2.3 

Personnel selection and qualification 

The device can only be operated by staff accordingly skilled and instructed.  
Work on electrical equipment of the device must be performed by a qualified electrician or trained 
individuals  under  the  direction  and  supervision  of  an  electrician  according  to  electro-technical 
regulations. 

 
2.4 

Safety Instructions for specific operating phases 

The device can only be operated in a safe and absolutely reliable state. Make sure in particular that 
all protective and safety-oriented devices are in place and fully functional. 
Loosened screws and hose connections must be tightened upon completion of the maintenance 
and repair work.  

 

2.5 

Mobile devices 

In case of minor changes of place, please even disconnect the device from any external power 
supply!

 

Properly reconnect to the mains prior to restarting the device! 

Always use hoisting and slinging equipment with sufficient weight bearing capacity for loading! 
Position hoisting devices or slinging means only on the load lifting appliances of the device that are 
provided for this purpose! 
Please take the necessary and appropriate measures for making sure that during the transportation 
no device part may fall in or loosen! 

 

2.6 

Safety instructions 

The removing of covers or parts of safety-oriented components may increase the risk of accident. 
Conversions,  maintenance  and  repair  work  must  be  performed  by  trained,  competent  and  skilled 
persons.  
Because of the risk of burns, make sure the device is always freely accessible and is not covered. 
Regularly  inspect/check  the  electrical  equipment  of  a  device.  Visible  faults,  such  as  loose 
connections, must be immediately rectified. 
 

Summary of Contents for ASG 1000

Page 1: ...01 2015 Subject to alterations 1 Operating Instructions Grinding Machine ASG 300 and ASG 1000 M ssel Maschinenbau GmbH Reichelsweiherstra e 8 95615 Marktredwitz GERMANY Tel 49 9231 9980 0 Fax 49 9231...

Page 2: ...to the latest state of technique and in compliance with this application Please find further information on splicing types and finishing parameters in the detailed splicing instructions or in the bel...

Page 3: ...ructions for specific operating phases 2 5 Mobile devices 2 6 Safety instructions 3 Product Description 3 1 Components and proper usage 3 2 Mode of operation 3 3 Technical data 3 4 Accessories 4 Prepa...

Page 4: ...Operating instruction B013 Edition 01 2015 Subject to alterations 4...

Page 5: ...s of the manufacturer M ssel Maschinenbau GmbH Reichelsweiherstra e 8 95615 Marktredwitz GERMANY 1 2 Identification of the machine Product designation Grinding machine Serial Type designation ASG 300...

Page 6: ...ket complies with the relevant essential health and safety requirements of the EU directive This declaration loses its validity upon the machine becoming altered or modified without the manufacturer s...

Page 7: ...y be used in proper technical condition as intended in a safety and hazard conscious manner and observing the operating instructions Observing the operating instructions and adhering to the inspection...

Page 8: ...ate Make sure in particular that all protective and safety oriented devices are in place and fully functional Loosened screws and hose connections must be tightened upon completion of the maintenance...

Page 9: ...or grinding the ends of splice in a wedge shape for example to prepare wedge splices The maxim width of belting material that can be worked is 300 mm or 1000 mm with a cut off angle of 60 the maximum...

Page 10: ...1000 Belt width max at 80 mm 270 970 Belt width max at 60 mm 160 830 Belt thickness max mm 8 8 Length mm 560 560 Width mm 680 1 165 Height mm 310 400 Weight net kg 32 0 42 0 Voltage V 230 230 Capacity...

Page 11: ...ing points 4 1 Position Grinding machines and their components may only be put on surfaces that are suitable for fabricating The surfaces must also be able to withstand the static load from the weight...

Page 12: ...mm at a cut off angle of 60 5 2 Adjusting grinding machine 1 Put the grinding machine down on an even pad 2 Position the belt grinder parallel to the grinding table and adjust them in such a way that...

Page 13: ...d stripe of double sided adhesive tape rearward the first stripe 4 Remove the membrane from the adhesive tape 5 Loosen the expander by opening the knurled head bolt 6 Please insert the prepared belt m...

Page 14: ...h a way that the front belting edge is slightly in contact 5 4 Bevelling the first end of the splice carrying side to the top 1 Switch the belt grinder on 2 Position the belt grinder so far downwards...

Page 15: ...rds loosen the expander and remove the belt Note It is easier to remove the belt material while using a brush with some ethyl alcohol between the double sided tape and the belt material 7 Please clean...

Page 16: ...grinding table for cleanliness Check grinding belt for wear and tear Check every twelve months According to VDE guideline 0701 0702 or the appropriate electrical engineering norms in the individual c...

Reviews: