background image

CONNECTIONS

Nu-Vista M

3

Instructions for Use.  Page 6 of 10  

WARNING

THE NU-VISTA  M

3

IS A POWER-

FUL AMPLIFIER AND IS
DESIGNED TO SUPPLY HIGH
VOLTAGES AND HIGH CUR-
RENTS THROUGH THE LOUD-
SPEAKER TERMINALS.
THEREFORE TO AVOID ANY
POSSIBILITY OF AN ELECTRIC
SHOCK DO NOT TOUCH THE
SPEAKER TERMINALS WHEN
THE UNIT IS BEING USED.

issue 1/26.10.2000

CONNECTIONS

All connections should be made with the
power OFF, i.e. before the mains lead is
plugged in and the unit switched on.

PSU to Amplifier Connections

The Nu-Vista M

3

is supplied with 2 com-

plete sets of power supply connecting leads.

One of the sets is 0.7M long the other 1.2M
long.  Choose the length that best suits your
installation.

The two power amplifier PSU leads are
identical.  

a)

One of these leads connects the right

PSU output to the right PSU input on the
amplifier.  

b)

The other one connects the left PSU

output to the left PSU input on the 
amplifier.  

Push the connectors into the sockets and
twist until they click in to place.

c)

The third lead in each set is to con-

nect the preamp PSU output to the preamp
PSU input on the main amplifier.  Push the

connectors into the sockets.

How to connect your Nu-Vista M

3

for

Normal Stereo use.

LINE LEVEL I/P CONNECTION

The Nu-Vista M

3

has 5 line level inputs -

CD, Tuner, Aux, SACD, and Tape.
and 1 phono input which can be used for
moving magnet (MM) cartridges.

All line level inputs are electrically identi-
cal and are suitable for use with any source
component with an output voltage in the
hundreds of millivolts (mV).  This
includes CD players, Super Audio CD
players (SACD), tuners, tape machines and
the audio outputs of video recorders, tele-
visions, DVD and LaserDisc players etc.

Connect the Left and Right outputs from
your line level sources to the line level
inputs on the back panel.  

For the best results we recommend that
you use Musical Fidelity Nu-Vista inter-
connect cables for this connection.

PHONO CONNECTION

The Nu-Vista M

3

has a phono input for

turntables fitted with a moving magnet car-
tridge (MM).  

Some turntable/pick-up arm combinations
are fitted with an extra wire called a chas-
sis earth, which should be connected to the
gold terminal on the back of the amplifier.

SPEAKER CONNECTION

Connect your loudspeakers to the loud-
speaker terminals situated on the back
panel marked as Left and Right
Loudspeaker Outputs.  We recommend that
you use Musical Fidelity Nu-Vista O.C.C
speaker cables for this connection.

MAINS CONNECTION

Once these connections are made, plug in
the 16A IEC type mains lead supplied with
the unit.

Summary of Contents for Nu-Vista M3

Page 1: ...ld give you many years of outstanding musical reproduction The Nu Vista M3 operates in Class A B which in our experience offers the ultimate in musical accuracy and pleasure For the best results Nu Vista interconnects and loudspeaker cables should be used Dust regularly with a soft duster or soft brush but be careful using cleaning or polishing agents they may harm the surface finish If you have a...

Page 2: ...ured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black If connecting to a BS1363 plug a 13 amp fuse must be used WARNING Radio Frequency Interference RFI This hi fi product has been tested to ensure that its operation will not be adversely affected by normal background levels of RFI It is possible that if this product is subje...

Page 3: ...it Do not place the unit near direct heat sources such as radiators or other equipment that produces heat Do not place the unit where it can be subjected to direct sun light Do not remove any covers or try to gain access to the inside The warranty is invalid if the unit has been tampered with There are no user adjustments within Refer all service work to an authorised Musical Fidelity agent Dust r...

Page 4: ...5 Infra red receiver lens 6 Right PSU LED 7 Right Preamp power LED 8 Input select control Nu Vista M3 back panel layout 9 RIGHT speaker outputs 10 PREAMP output 11 TAPE RECORD output 12 TAPE input 13 AUX input 14 Tuner input 15 SACD input 16 CD input 17 Phono input 18 LEFT speaker outputs 19 Right power amp PSU input 20 Preamp PSU input 21 Phono earth terminal 22 Left power amp PSU input 1 2 3 4 5...

Page 5: ...PSU front panel layout 1 Mains on off switch 2 Power LED Nu Vista M3 PSU back panel layout 3 Right power amp PSU output 4 Preamp PSU output 5 Left power amp PSU output 6 Right power amp PSU fuse 7 Preamp PSU fuse 8 Left power amp PSU fuse 9 16A mains inlet issue 1 26 10 2000 P O W E R S U P P L Y U N I T ...

Page 6: ...ista M3 for Normal Stereo use LINE LEVEL I P CONNECTION The Nu Vista M3 has 5 line level inputs CD Tuner Aux SACD and Tape and 1 phono input which can be used for moving magnet MM cartridges All line level inputs are electrically identi cal and are suitable for use with any source component with an output voltage in the hundreds of millivolts mV This includes CD players Super Audio CD players SACD...

Page 7: ...between the PSU and the amplifier 3 After approx 20 seconds the Nuvistas will have heated up and the mute will switch off automatically 4 You can now and carefully advance the volume to the level you want and enjoy the music issue 1 26 10 2000 REMOTE CONTROL The Nu Vista M3 features Infra Red remote control of volume input selection and mute functions via the supplied remote control handset The In...

Page 8: ...o work If you are in any doubt consult your tape machine s manual issue 1 26 10 2000 PREAMP OUTPUT The Nu Vista M3 has a permanently active preamp output situated on the back panel This provides extra flexibility for use in multi room or surround sound sys tems etc This signal comes from the Nu Vista M3 s internal preamp and its output level is thus controlled by the front panel volume control Thi...

Page 9: ...securely One or more LEDs does not light when power is pressed PSU to Amplifer leads not connected correctly Check Connections No sound Volume control is set to minimum Turn up the volume Wrong input selected Select correct input Mute is selected Press mute button on remote control Unit has not yet come out of power up mute Wait 15 20 seconds on power up for unit to un mute Tape Monitor button is ...

Page 10: ...s Typically 102dB A weighted S N Ratio MM Typically 83dB A weighted Power consumption 1200W Power requirements 100 115 230V AC 50 60Hz Factory preset Dimensions Amplifier 482 x 145 x 470mm W x H x D Height includes feet Depth includes terminals PSU 365 x 145 x 250mm W x H x D Height includes feet Depth includes terminals Weight approx Amplifier 23kg un boxed PSU 16kg un boxed Nu Vista M3 Instructi...