![Musical Fidelity M6 VINYL Instruction Manual Download Page 8](http://html.mh-extra.com/html/musical-fidelity/m6-vinyl/m6-vinyl_instruction-manual_1858900008.webp)
MM / MC
PHONO STAGE
ViNYL
8
Problem
Probable Cause
Remedy
No power .
Power plug is not inserted into
socket correctly .
Plug in securely into unit’s IEC socket .
No sound .
Wrong connections between
inputsources and the unit .
Cartridge incorrectly wired .
Check audio input and output lead connections .
Check cartridge wiring .
Sound too quiet/loud.
Wrong MM/MC cartridge
selection .
Use MM setting for MM cartridges .
Use MC setting for MC cartridges .
Sound is not precise,
lacking in bass and
stereo image .
Cartridge incorrectly wired .
Input connector plugs not fully
pushed in .
Output connector plugs not fully
pushed in .
Check turntable tracking weight and cartridge setup .
Check plugs are inserted fully and securely .
Hum .
Turntable not earthed or needs
earthing .
Turntable already earthed and
earthing
further creates hum loop in
system .
Earth loops already in system
being amplified.
Audio connector plug not fully
pushed in
Cable fault .
Unsuitable Cable
(e .g . cable grounds not
connected) .
Check turntable earthing lead is connected to earthing post .
Disconnect earthing lead from earthing post .
Investigate for earth loops elsewhere in system .
Insert plug securely and check cable is connected at both ends .
N .B . some esoteric cables have internal wiring intentionally disconnected/
modified. For best results on all inputs AND outputs, please use good
quality screened coax; fully connected signal-to signal, screen-to-screen.
Pop or click heard in
speakers
when switching on or
off or
changing options .
High gain of M6 ViNYL,
amplifying normal
circuit transients .
Not a fault. It is recommended that the volume level on amplifier is turned
down if switching the M6 ViNYL on or off; or pressing option switches whilst
connected .
Distorted sound .
Cartridge and/or tone arm not
aligned properly .
Cartridge fault or worn needle .
Dirt on record .
Carefully follow turntable instructions to correctly re-align tone arm and
cartridge .
Replace needle or cartridge .
Clean dust and dirt from record .
Distorted and loud
sound .
Line outputs of M6 ViNYL
plugged into PHONO amplifier
inputs of following amplifier.
Use LINE level inputs only, e.g. an AUX input.
Troubleshooting
If none of these actions affect a cure, please contact the dealer, or an authorised Musical Fidelity
service agent .
Remember; never open the case of the M6 ViNYL, as this will invalidate the warranty .