SAFETY INFORMATION

IMPORTANT!

This unit is supplied in the U.K. with a mains lead fitted with a moulded 13 amp plug.

If, for any reason, you need to cut off this plug, please observe the following safety precautions.
Please dispose of the cut-off plug safely.  It must not be plugged into a mains power supply. 

The wires in the mains lead supplied with this appliance are coloured in accordance

with the following code:

Green and yellow..............Earth 
Blue...............................Neutral 
Brown................................Live

WARNING - This appliance must be earthed

As the colours of the wires of the mains lead of this appliance may not correspond with the
coloured markings identifying the terminals in your plug, proceed as follows:

The wire which is coloured green-and-yellow must be connected to the terminal in the plug
which is marked with the letter E or coloured green or green-and-yellow, or by the earth 

symbol.

The wire which is coloured brown must be connected to the terminal which is marked with the
letter L or coloured red.

The wire which is coloured blue must be connected to the terminal which is marked with the
letter N or coloured black.

If connecting to a BS1363 plug, a 10 amp fuse must be used.

WARNING - Radio Frequency Interference (RFI)

This hi-fi product has been tested to ensure that its operation will not be adversely affected by
normal background levels of RFI. It is possible that if this product is subjected to abnormally
high levels of RFI the unit may be susceptible and not perform as expected.  In the unlikely
event of this happening on a regular basis, please contact Musical Fidelity's service department.
The unit has also been tested to ensure that it does not radiate excessive levels of RFI that could
affect other pieces of electronic or electrical equipment.
The electronics in modern hi-fi equipment is complex and hence may be damaged by lightning.
It is possible that during electrical storms the operation of some equipment may be adversely
affected.  For complete protection of your hi-fi system during such storms, mains plugs and aer-
ial leads should be disconnected.  

Always ensure that when disconnecting and re-connecting your hi-fi equipment the mains 
supply is switched off.

issue 1/12.07.2000

Summary of Contents for HT600

Page 1: ...lifier specifically designed for home theatre applications It has been developed to operate with all Musical Fidelity preamplifiers but especially the HTP home theatre processor Used properly and carefully it should give you many years of outstanding musical reproduction Aesthetically the HT600 is a perfect match for the HTP home theatre processor HT600 5 Channel Power Amplifier issue 1 12 07 2000...

Page 2: ... L or coloured red The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black If connecting to a BS1363 plug a 10 amp fuse must be used WARNING Radio Frequency Interference RFI This hi fi product has been tested to ensure that its operation will not be adversely affected by normal background levels of RFI It is possible that if this produc...

Page 3: ...he following ranges Temperature 5 to 45 degrees Celsius Humidity 10 to 90 non condensing Position the mains lead and all interconnects where they are not likely to be walked on or trapped by items placed on them Do not use near water The unit shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the unit Do not place the unit near direct ...

Page 4: ...IN ENGLAND BY MUSICAL FIDELITY LEFT SURROUND INPUT LEFT OUTPUT POWER CONSUMPTION 1200W LEFT INPUT 7 8 9 10 11 12 13 14 15 16 17 1 ON OFF mains switch 2 Left channel blue LED 3 Left surround channel blue LED 4 Centre channel blue LED 5 Right surround channel blue LED 6 Right channel blue LED6 7 Right front line level input 8 Right surround line level input 9 Centre channel line level input 10 Left ...

Page 5: ...o nonsense interconnect cables for this connection or the highly rated Nu Vista interconnects with integral RFI suppression Various lengths are available in the Nu Vista interconnect range Please contact your local dealer for more information OUTPUT CONNECTIONS All connections should be made with the power OFF Connect your loudspeakers to the loudspeaker terminals situated on the back panel marked...

Page 6: ...hannel power amplifier Instructions for Use Page 6 of 7 ALL 5 Blue LEDs do not light Power cord disconnected Re connect Mains switch switched off Switch on One of the Blue LEDs does not light Unit has a fault Switch off and refer back to you dealer Sound is not precise lacking in bass and stereo image Speakers are connected out of phase Make sure that all speakers are connected correctly If none o...

Page 7: ...hannel separation 85dB 20Hz 20kHz Input sensitivity 1000mV Input impedance 31KOhm S N ratio 100dB A weighted Ref 1W 120dB A weighted full output Power consumption 1200W Max Dimensions Amplifier 440 x 95 x 400mm W x H x D Height includes feet depth includes terminals Power requirements 100 115 230V AC 50 60Hz Factory preset Weight 16 kg un boxed Standard accessories IEC type mains lead Musical Fide...

Reviews: