Section 80
00-02-0829
2018-02-26
-
52 -
This CAN message is broadcast by the PDM to communicate the settings of a group of output channels.
Depending on the Feedback and Diagnostics Identifier byte, the message pertains to Output Channels 1-6 or 7-
12 respectively.
Transmission Repetition
20 – 500 ms
Data Length
8 bytes
Data Page
0
PDU Format (PF)
239
Proprietary A, PDU1 format
PDU Specific (PS)
17 (11h)
DA (Source Address of the configuring display or
controller)
Priority
5
Parameter Group Number
61184 (EF00h) -
Feedback and Diagnostics
Start Position Length
Parameter Name
Reference
5.2
1 bit
Automatic Reset (Output Channel 4 or 10)
5.1
1 bit
High-Side or H-Bridge (Output Channel 4 or 10)
6.5
4 bits
Current Limit (Output Channel 5 or 11)
6.3
2 bits
Feedback Type (Output Channel 5 or 11)
6.2
1 bit
Automatic Reset (Output Channel 5 or 11)
6.1
1 bit
High-Side or H-Bridge (Output Channel 5 or 11)
7.5
4 bits
Current Limit (Output Channel 6 or 12)
7.3
2 bits
Feedback Type (Output Channel 6 or 12)
7.2
1 bit
Automatic Reset (Output Channel 6 or 12)
7.1
1 bit
High-Side or H-Bridge (Output Channel 6 or 12)
8
1 byte
Reserved (always FFh)