Relays, Timers, and Sensor Input Class 

Ordering Your Configuration

Sensor Input

Specify Class

Specify Function

Default Nomenclature

User Specified Nomenclature

Example:

Class B2

SD

Compressor Oil Pressure

Compressor #1  Oil Pressure

Input 1

____________

_________________

Compressor Oil Pressure

________________________

Input 2

____________

_________________

Compressor Oil Level

________________________

Input 3

____________

_________________

Lubrication No-Flow

________________________

Input 4

____________

_________________

Low Suction Pressure

________________________

Input 5

____________

_________________

Interstage Pressure #1

________________________

Input 6

____________

_________________

Interstage Pressure #2

________________________

Input 7

____________

_________________

Interstage Pressure #3

________________________

Input 8

____________

_________________

Discharge Pressure

________________________

Input 9

____________

_________________

Discharge Temperature #1

________________________

Input 10

____________

_________________

Discharge Temperature #2

________________________

Input 11

____________

_________________

Discharge Temperature #3

________________________

Input 12

____________

_________________

Discharge Temperature #4

________________________

Input 13

____________

_________________

Suction Liquid Level

________________________

Input 14

____________

_________________

Interstage Liquid Level #1

________________________

Input 15

____________

_________________

Interstage Liquid Level #2

________________________

Input 16

____________

_________________

Interstage Liquid Level #3

________________________

Input 17

____________

_________________

Inlet Scrubber Liquid Level

________________________

Input 18

____________

_________________

Engine Oil Pressure

________________________

Input 19

____________

_________________

Engine Oil Level

________________________

Input 20

____________

_________________

Engine Oil Vibration

________________________

Input 21

____________

_________________

Engine Jacket Water Temp.

________________________

Input 22

____________

_________________

Engine Jacket Water Level

________________________

Input 23

____________

_________________

Engine Jacket Water Press.

________________________

Input 24

____________

_________________

Engine Vacuum Right Bank

________________________

Input 25

____________

_________________

Engine Vacuum Left Bank

________________________

Input 26

____________

_________________

Compressor Vibration

________________________

Input 27

____________

_________________

Cooler Vibration

________________________

Input 28

____________

_________________

Cooler Water Level

________________________

Input 29

____________

_________________

Auxiliary Pump Shutdown

________________________

Input 30

____________

_________________

Emergency Shutdown

________________________

Input 31

____________

_________________

PLC Shutdown

________________________

Input 32

____________

_________________

Prelube Permissive

________________________

Use the listings below to specify sensor input Class, Function and Nomenclature; the S1500 sensor inputs are factory-configured as follows:

Class A: Armed at all times for alarm or shutdown (specify).

Class P: Locked out by the Compressor Load lockout timer.

Class B1Locked out by first lockout timer (First Start/Run timer).

ESD: Overrides the Test lockout timer (for Remote/Emergency Stop input).

Class B2: Locked out by second lockout timer (Second Start/Run timer).

SD: S1500 System Shutdown Function.

Class C: Armed after fault condition has been cleared for 2 seconds.

AL: Alarm Relay Function (no shutdown).

Select your Relay Logic Mode (see page 4):

MODE No. ____________________

Select your Timing and range; (default values)

TACHOMETER

Pulses/Rev.: _____________________ (60)

Crank Disconnect: _______________ (100)

Underspeed: ____________________ (150)

Overspeed: _____________________ (400)

TIMERS

Prelube: ___________________ (0:30)

Run Delay: _________________ (0:30)

Class B1: ___________________ (1:00)

Class B2: ___________________ (1:00)

Load Delay: _________________ (1:00)

Process Delay: _______________ (1:30)

Idle/Cooldown: _______________(5:00)

Ignition Ground: _______________ (0:10)

Postlube: ______________________ (0:30)

CRANKING

Attempts: ______________________ (5)

Crank Period: __________________ (0:15)

Rest Period: ____________________ (0:15)

DISCONTINUED

Summary of Contents for Selectronic Micro-Controller Series 1500

Page 1: ... safe outputs Applications The Series 1500 can be configured to monitor applications such as Generators Air compressors Process control Gas compressors Water treatment Fire pumps Burner systems Sewage pumps Natural gas refueling Features 32 sensor inputs N O and or N C for alarm or shutdown Six button keypad for easy operation and adjustments RS232 output for interface with computers and micro con...

Page 2: ...tic 1 4 DIN 90 x 90 mm Interface Output RS232 communication port Alphanumeric Display 2 lines each line with 16 characters 32 total Laboratory Approvals CSA and NRTL C for Cl I Div 1 Grps C D Power Supply Enclosure Explosion proof Class I Division 1 Intrinsically safe barrier built into power supply 120 VAC and 12 or 24 VDC power supply barrier with dry contact relay functions such as Fuel valve A...

Page 3: ...___ Input 22 ____________ _________________ Engine Jacket Water Level ________________________ Input 23 ____________ _________________ Engine Jacket Water Press ________________________ Input 24 ____________ _________________ Engine Vacuum Right Bank ________________________ Input 25 ____________ _________________ Engine Vacuum Left Bank ________________________ Input 26 ____________ _____________...

Page 4: ...4 K2 K3 K1 K4 K3 K2 K1 Logic Modes Motor Ignition Cooler Load Shutdown Lube Crank Alarm Fuel Printed in U S A FRANK W MFR Frank W Murphy Manufacturer P O Box 470248 Tulsa Oklahoma 74147 USA tel 918 627 3550 fax 918 664 6146 e mail fwmurphy ionet net Frank W Murphy Southern Division P O Box 1819 Rosenberg Texas 77471 USA tel 281 342 0297 fax 281 341 6006 e mail murphysd intertex net Since 1939 Fran...

Reviews: