background image

 

00-02-0795 

- 21 - 

10-18-11 

9. A 

modified

 Reminder

 displays a (

+

) at right of 

Reminder

 name when successfully completed. Follow 

the above steps to modify other 

Reminders

When finished, touch 

Menu

 to return to the 

Main 

Menu. 

Select Units 

From SELECT UNITS, you may select how information is 
displayed:  

  

ENGLISH

 for Imperial units (PSI, 

F)  

  

METRIC KPA

 

  METRIC BAR

 for 

IS

 units (kPa, Bar, 

C). 

Backlight Adjustment 

ADJUST BACKLIGHT allows you to select the desired 
backlight intensity. 

Contrast Adjustment 

From ADJUST CONTRAST, you may select the desired 
contrast intensity. 

Summary of Contents for PowerView PV-101-A

Page 1: ...10 18 11 00 02 0795 Section 78 PowerView Model PV 101 A V2 3 User s Guide...

Page 2: ...ted warranty on materials and workmanship is given with this FW Murphy product A copy of the warranty may be viewed or printed by going to www fwmurphy com support warranty htm BEFORE BEGINNING INSTAL...

Page 3: ...Transmission Parameters 2 Faceplate Features 3 Navigation and Keypad Functions 4 Operation 9 PowerView Menus First Time Start Up 9 Setting up the Display 12 Main Menu Options 18 Utilities Menu 22 OEM...

Page 4: ...Set Source Address 28 Restore All Defaults 29 Clear Machine Hours 29 Set Machine Hours 29 Faults and Warnings 31 Troubleshooting 34...

Page 5: ...ice codes of modern electronic engines and transmissions This guide is intended to help you set up your PowerView display and identify navigation basics and product features The display s simple navig...

Page 6: ...applicable consult engine or transmission manufacturer for SAE J1939 supported parameters Engine RPM Engine hours System voltage Percent engine load at the current RPM Coolant temperature Oil pressur...

Page 7: ...00 02 0795 3 10 18 11 Faceplate Features...

Page 8: ...itches to wear or stick The keys on the keypad perform the following functions Menu Enter or exit menu screens Left Arrow Scroll the screen or move the parameter selection to the left or upward Right...

Page 9: ...00 02 0795 5 10 18 11 Basic Navigation 1 When Menu is pressed the main menu items are displayed...

Page 10: ...00 02 0795 6 10 18 11 2 Touching the Arrow Keys will move the selection bar to other menu items...

Page 11: ...00 02 0795 7 10 18 11 3 Certain menus have multiple pages of items Scrolling past the top item or bottom item on the current page will reveal other menu items on additional pages...

Page 12: ...lighted by the cursor pressing Enter will select that item and display the corresponding screen 5 Anytime the word NEXT appears above the Arrow Keys there are more screens that may be viewed Use the A...

Page 13: ...00 02 0795 9 10 18 11 Operation PowerView Menus First Time Start Up 1 When power is first applied to the display the Murphy logo appears...

Page 14: ...shown Engine manufacturers typically recommend against starting the engine while this message is broadcast from the ECU Once the ECU stops broadcasting this message this screen will no longer be disp...

Page 15: ...00 02 0795 11 10 18 11 Pressing the Right Arrow Key will display the coolant temperature The screen can be changed to other parameters by pressing Menu...

Page 16: ...on of the 1 Up display Use Defaults This option contains a set of engine parameters Engine Hours Engine RPM System Voltage Battery Voltage Engine Load at Current RPM Coolant Temperature and Oil Pressu...

Page 17: ...To select CUSTOM SETUP highlight the option and press Enter A list of engine parameters is displayed 4 To select a parameter use the Arrow Keys to scroll and highlight the parameter then touch Enter S...

Page 18: ...eturn to the CUSTOM SETUP menu 7 Selecting the AUTOMATIC SCAN ON function will cause the 1 up display to scroll through the selected set of parameters one at a time 8 Once the USE DEFAULTS CUSTOM SETU...

Page 19: ...th parameters you define for each quadrant 1 Touch Menu and use the Arrow Keys to highlight SETUP 4 UP DISPLAY then press Enter 2 To select USE DEFAULTS highlight the option and press Enter A message...

Page 20: ...umber to the right of the parameter indicates the quadrant in which it is displayed 1 upper left quadrant 2 lower left quadrant 3 upper right quadrant 4 lower right quadrant 6 Use the Arrow Keys to hi...

Page 21: ...00 02 0795 17 10 18 11 8 The parameter in the selected quadrant has changed to the parameter selected in the previous screen 9 Repeat the parameter selection process until all spaces are filled...

Page 22: ...nguage From LANGUAGES you may select ENGLISH ESPANOL FRANCAIS ITALIANO or DEUTSCH The currently selected language is indicated by an asterisk Stored Fault Codes Select this and PowerView requests and...

Page 23: ...re internal reminders within PowerView Once a Service Reminder is active warnings will show SPN 916 and FMI 17 Check PowerView Service Reminders prior to calling Technical Support 1 Use the Arrow Keys...

Page 24: ...ify and touch Enter 6 The Reminder name appears at top screen The hour value displays mid screen and allows you to set the number of hours to elapse before a Reminder prompts Bottom screen shows Cance...

Page 25: ...d touch Menu to return to the Main Menu Select Units From SELECT UNITS you may select how information is displayed ENGLISH for Imperial units PSI F METRIC KPA METRIC BAR for IS units kPa Bar C Backlig...

Page 26: ...configuration Gage Data View information for optional connected PVA gages Remove All Gages Reset the gage memory on the PowerView Software Version This screen lists Configuration Firmware Languages a...

Page 27: ...ouch Enter to toggle between master and slave 3 Select SERIAL PORT SETUP slave mode only then touch Enter 4 Continue to scroll each selection BAUD RATE PARITY DATA BITS and STOP BITS to configure the...

Page 28: ...lt change to a different J1939 Version If the fault SPN does not change when the version is changed the ECU generating the fault is using Fault Conversion method 4 If the SPN number does change but is...

Page 29: ...eft Arrow Key to decrease the percentage of remaining fuel at which to send a warning The default is 20 NOTE The PowerView accepts optional Murphy fuel sender recommend Model ES2F for fuel level infor...

Page 30: ...eric spaces provided Start at the furthest left numeric value and use the Left Arrow Key to increment the number and the Right Arrow Key to move to the next numeric position The following items are in...

Page 31: ...rough the Serial Port Setup list and make selections for BAUD RATE PARITY DATA BITS and STOP BITS to configure the serial port parameters for your Modbus slave application CANBUS Data Rate Touch Enter...

Page 32: ...uch the Arrow Keys to scroll through the selections 0 253 and ALL 3 Once the target address displays touch Enter 4 A confirmation screen displays selecting NO Menu returns to the SELECT ENGINE ECU scr...

Page 33: ...FACTORY DEFAULTS displays when this is selected Clear Machine Hours Use this to clear machine hours internal to PowerView outside of ECU hours Set Machine Hours Machine hours calculate internally whe...

Page 34: ...tpoints Clear Fuel Setpoints or choose to set the fuel setpoints for and fuel tank levels Fuel Setpoints must be ON to work with a non Murphy fuel sender Modifying fuel setpoints is a complex process...

Page 35: ...rnings The PowerView provides two means for detecting faults and warnings visual LEDs on the casing See Faceplate Features and fault indicators on the display Visual Indication Amber LED Warning Red L...

Page 36: ...ONDING NOTE The fault can only be cleared by correcting the cause of the fault condition Active Fault Codes When the PowerView receives a fault code from an engine the 1 up or 4 up display will be rep...

Page 37: ...nd return to the 1 up or 4 up display touch Enter The display will return to the 1 up or 4 up display but the display will contain the shutdown icon 2 Touch Enter to redisplay the hidden fault Touch E...

Page 38: ...le the ECU is broadcasting this message Once the ECU stops broadcasting this message this screen will no longer be displayed on the PowerView CANBUS FAILURE The PowerView has not received any valid J1...

Page 39: ...place of a parameter value NO DATA The PowerView has not received data for the selected parameter for at least 5 seconds NOT SUPPORTED The ECU is sending a message that it does not support this param...

Page 40: ...adrants is empty No parameter has been selected for display in this quadrant Display is not readable either very dim or very dark The LCD contrast may have been over or under adjusted Press and hold t...

Page 41: ...00 02 0795 37 10 18 11 NOTES...

Page 42: ...This document including textual matter and illustrations is copyright protected by Murphy Industries Inc with all rights reserved 2011 Murphy Industries LLC Other third party product or trade names re...

Reviews: