4.3
Electrical installation
4.4
Mains power supply
Check that the unit is connected to the correct mains power supply voltage, and that it is protected by
the correct fuse size. A protective earth connection must be made, in accordance with regulations.
Rating plate with supply connection data
Tradesmig 171
Tradesmig 201
Tradesmig 251
Voltage V
220--230V,
1
∼
50/60Hz
220--230V,
1
∼
50/60Hz
220--230V,
1
∼
50/60Hz
Current A
at 100% duty cycle
12,0
13,0
16,6
at 60% duty cycle
15,7
18,2
23,4
at @% duty cycle
27,8 @ 25%
36,2 @ 23%
38,7 @ 30%
at 20% duty cycle
29,7
39,0
47,5
Cable area mm
2
2
2
2
3 x 1.5
3 x 2.5
3 x 4,0
Fuse
slow
A
16
20
35