background image

ENGLISH

-- 3 --

TOCe

1 SAFETY

4

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 INTRODUCTION

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2.1

Equipment

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3 TECHNICAL DATA

6

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4 INSTALLATION

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.1

Placing

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.2

Assembly of components

7

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.3

Electrical installation

8

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4.4

Mains power supply

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5 OPERATION

9

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.1

Connection and control devices

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.2

Functions explanation

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6 MAINTENANCE

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.1

Inspection and cleaning

10

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7 FAULT TRACING

11

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DIAGRAM

12

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

WEAR COMPONENTS

14

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ACCESSORIES

15

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Rights reserved to alter specifications without notice.

Summary of Contents for Tradesmig 141

Page 1: ...Valid for serial no 811 0349 301 142 080424 Tradesmig 141 Instruction manual ...

Page 2: ...requirements of Council Directive 89 336 EEC amended by Council Directive 93 68 EEC relating to electromagnetic compatibility S are manufactured in accordance with EN60974 1 Safety Requirements for Arc Welding Equipment S are manufactured in accordance with EN60974 10 Electromagnetic Compatibility for Arc Welding Equipment On behalf of oMurex Welding Products Ltd Hanover House Queensgate Hanover H...

Page 3: ...ly of components 7 4 3 Electrical installation 8 4 4 Mains power supply 9 5 OPERATION 9 5 1 Connection and control devices 10 5 2 Functions explanation 10 6 MAINTENANCE 10 6 1 Inspection and cleaning 10 7 FAULT TRACING 11 DIAGRAM 12 WEAR COMPONENTS 14 ACCESSORIES 15 Rights reserved to alter specifications without notice ...

Page 4: ...n S location of emergency stops S its function S relevant safety precautions S welding 2 The operator must ensure that S no unauthorised person is stationed within the working area of the equipment when it is started up S no one is unprotected when the arc is struck 3 The workplace must S be suitable for the purpose S be free from draughts 4 Personal safety equipment S Always wear recommended pers...

Page 5: ...h suitable screens or curtains FIRE HAZARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears Use earmuffs or other hearing protection S Warn bystanders of the risk MALFUNCTION Call for expert assistance in the event of malfunction PROTECT YOURSELF AND OTHERS WARNING Read and understand the...

Page 6: ...lamp S Instruction manual 3 TECHNICAL DATA Tradesmig 141 Voltage 230 240V 1 50 60Hz Permissible load at 100 duty cycle 42A 16 1V 60 duty cycle 54A 16 7V 20 duty cycle 100A 17 0V Setting range DC 35A 15 7V 83A 18 2V 130A 13 4 Open circuit voltage 18 7 25 1V Open circuit power 75W Power factor at max load 0 91 Control voltage 230 240V 50 60Hz Wire feed speed 2 0 14m min Welding gun connection fixed ...

Page 7: ... designed for indoor and outdoor use Application class The symbol indicates that the power source is designed for use in areas with increased electrical hazard 4 INSTALLATION The installation must be executed by a professional 4 1 Placing Position the welding power source such way that its cooling air inlets and outlets are not obstructed 4 2 Assembly of components ...

Page 8: ... 8 T141e 4 3 Electrical installation ...

Page 9: ...slow A 10 NB The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations They may not be applicable in other countries make sure that the cable area and fuse sizes comply with the relevant national regulations 5 OPERATION General safety regulations for the handling of the equipment can be found on page 4 Read through before you start using the equipment WARNING R...

Page 10: ...the front of the ma chine It resets automatically when the temperature has fallen 6 MAINTENANCE Regular maintenance is important for safe reliable operation Note All guarantee undertakings from the supplier cease to apply if the customer himself attempts any work in the product during the guarantee period in order to rectify any faults 6 1 Inspection and cleaning Check regularly that the power sou...

Page 11: ...k the main power supply fuses Thermal overload trips operate frequently S Check to see whether the air inlets outlets are clogged S Make sure that you are not exceeding the rated data for the power source i e that the unit is not being overloaded Poor welding performance S Check that the welding current supply and return cables are correctly connected S Check that the correct current value is set ...

Page 12: ...Diagram 12 dT141 Tradesmig 141 ...

Page 13: ...Tradesmig 141 Edition 080424 13 oT141 Valid for serial no 811 XXX XXXX Ordering numbers 0349 311 670 Tradesmig 141 230 240V 1 50 60Hz ...

Page 14: ... cored wire CuSi Al C Contact tip 0700 200 063 0700 200 064 0349 311 442 Ø 0 6mm Fe Ø 0 8mm Fe cored wire CuSi Ø 1 0mm Al The rollers are marked with wire dimension in mm some are also marked with inch Welding with aluminium wires In order to weld with aluminium wires proper rollers nozzles and liners for aluminium wires MUST be used It is recommended to use 3m long welding gun for aluminium wires...

Page 15: ...Tradesmig 141 Edition 080424 Accessories 15 aT141 Traction KIT 0349 309 073 ...

Reviews: