Murdock AI81.8 Series Installation And Maintenance Instructions Manual Download Page 2

Page 2 of 8

AI81.8

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

ELECTRIC DRINKING FOUNTAINS

Revised: 

03/29/2021

7020-007-001 

RVB

ROUGHING-IN AND DIMENSIONAL DRAWING

Prior to roughing consult with local, state, and federal codes for proper mounting height. 

  

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

 GENERAL NOTES:
 1. ALL DIMENSIONS ARE IN INCHES [MM]

*2. DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HEIGHT, ADJUST VERTICAL

DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL, STATE, & LOCAL CODES

 3. STOP VALVE NOT PROVIDED
 4. WATER LINE FROM CHILLER TO FOUNTAIN SHOULD BE COVERED WITH SPONGE
     FOAM RUBBER OR ICE WATER TYPE INSULATION OF ADEQUATE THICKNESS

33

1
2

"

(851)

52

1
2

" (1334)

FRAME

29" (373)

WASTE

OUTLET

27" (686) ADA

MIN WALL

OPENING

1

3
8

"

79

1
2

" (2019)

SUPPLY

INLET

17" (432) ADA

MIN WALL

OPENING

24"

(610)

31

1
2

"

(800)

17" (432)

WALL

OPENING

12" (305)

WALL

OPENING

5
8

" (16)

55

1
2

"

(1410)

2" (51)

CL

4

7
8

"

(124)

4

3
4

" (121)

8

3
4

"

(222)

CL

19" (483)

36" (914) ADA MIN

WALL OPENING

2"

(51)

53" (1346)

WALL

OPENING

1
4

" (6)

MOUNTING FRAME
PROVIDED

29"

(737)

1

1
2

" (38)

1

3

1

4

5

1

ACCESS PANEL

OPTIONAL GLASS FILLER

RECESSED DRINKING FOUNTAIN

A9100080-A, 8 GPH CHILLER

1-1/2" SLIP JOINT WASTE

CONNECTION

2

2

1

3

4

5

2

SHOWN

Summary of Contents for AI81.8 Series

Page 1: ...l or direct charges caused by defects in the materials or any delay in the repair or replacement thereof This warranty is in lieu of all other warranties expressed or implied Product maintenance instructions are issued with each unit and disregard or non compliance with these instructions will constitute an abnormal use condition and void the warranty Stainless steel must be protected on job site ...

Page 2: ...T ADJUST VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH FEDERAL STATE LOCAL CODES 3 STOP VALVE NOT PROVIDED 4 WATER LINE FROM CHILLER TO FOUNTAIN SHOULD BE COVERED WITH SPONGE FOAM RUBBER OR ICE WATER TYPE INSULATION OF ADEQUATE THICKNESS 331 2 851 521 2 1334 FRAME 29 373 WASTE OUTLET 27 686 ADA MIN WALL OPENING 13 8 791 2 2019 SUPPLY INLET 17 432 ADA MIN WALL OPENING 24 610 311 2 800 17 432 WALL...

Page 3: ...g the Tube from the Fitting ensure that the Water Line is depressurized Push Collet Square towards the Push In Fitting Body and hold While holding the Collet in pull on the PE Tubing to remove from the Push In Fitting TO CUT TUBE Cut to fit length of 1 4 PE Tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE ...

Page 4: ...e is 1 1 4 Outer Diameter Chiller water inlet is 3 8 Outer Diameter copper tube Chiller water outlet is 3 8 Outer Diameter copper tube Drinking Fountain water inlet is 1 4 Outer Diameter connection Bottle Filler water inlet is 1 4 Outer Diameter connection Water line by others from in wall chiller to drinking fountain must have adequate insulation 7 Power supply must be identical in voltage cycle ...

Page 5: ...5 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of IN OUT IN OUT 2 3 1 TO DRINKING FOUNTAIN 1 OUT IN 4 5 2 3 4 INSULATED 1 4 OD TUBING Y STRAINER ANGLE STOP BY OTHERS CHILLER w 3 8 OD TUBE INLET OUTLET CONNECTIONS OPTIONAL WF1 1500 GALLON WATER FILTER SHOWN WITH NOTE INSULATION TUBING MAY OVERLAP FITTINGS ILLUSTRATIONS MAY SHOW EXPOSED 1 4 OD TUBING FOR CLARITY ONLY 1 2 3 4 5 1 1 4 OD...

Page 6: ...sure Y strainer assembly is orientated in the proper direction of flow Refer to arrow on strainer 9 Make up Waste connection to drinking fountain 1 1 4 OD connection 2 Air within the Fountain or the structure supply piping will cause an irregular outlet stream until purged out by incoming water 1 Before assembling Access Panels to fixture but after thoroughly flushing the supply line and connectin...

Page 7: ...N S ELECTRIC DRINKING FOUNTAINS Revised 03 29 2021 7020 007 001 RVB MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of FRAME ASSEMBLY 6 FASTENERS BY OTHERS CHILLER LOUVERED ACCESS PANEL BOTTOM ACCESS PANEL EXPLODED VIEW ...

Page 8: ...ESCRIPTION 1 A0000000 MF7 CHILLER FOUNTAIN FRAME ASSY 2 A9100080 A CHILLER 3 7035 107 199 LOUVERED ACCESS PANEL 4 0279 002 000 8 32 x 3 4 L BUTTON HEAD SCREW 5 0322 001 000 8 32 LOCKWASHER STAR 7000 012 001 BUBBLER STAINLESS STEEL 7000 099 002 BUBBLER FLEXIBLE LOW FLOW 7 7000 050 001 CARTRIDGE VALVE ASSEMBLY 8 7000 060 000 CARTRIDGE FLOW REG 0 50 GPM 9 7000 091 001 CARTRIDGE PUSHBUTTON 10 7035 111...

Reviews: