PRIOR TO INSTALLATION:

Important: some options may slightly alter installation. To ensure proper installation review the manual 
thoroughly and verify rough-ins before beginning work. File this manual with the owner or maintenance 
personnel upon completion of installation.

 Fixture mounting requirements: industry standard wall construction, adequate to support the fixture and 

installer provided wall anchors sufficient to secure the fixture.

 Inspect fixture and all parts from damages.

IMPORTANT:

1.   Waste P-Trap, Water Supply Service Angle Stop Valve to be supplied by others in accordance with local 

codes. A metallic p-trap (by others) must be used for the drain connection.

2.   Water supply is 3/8” Outer Diameter copper tube. Waste is 1-1/4” Outer Diameter. 

3.   Completely flush supply lines of all foreign debris before connecting to fixture. Drinking fountain is 

designed to not cause problems with taste, odor, color, or sediment. Optional water filter (WF1) is 
available should any of these problems arise from the water supply. 

4.   Do NOT solder tubes inserted into the coupler as damage to the o-ring may result.

5.   All burrs must be removed from outside of cut tubes before inserting into coupler or other components. 

6.   Warranty is voided if installation is not made following current Acorn Engineering installation instructions 

and if components are assembled to the fixture that is not approved by Acorn Engineering. 

7.   Fixture operates within water pressure range of 20 to 105 psig. Acorn Engineering will not warranty 

fixtures damaged when connected to supply lines with flow pressure lower than 20 psig or higher than 
105 psig. A pressure regulator must be furnished by others on supply line if inlet  pressure is greater than 
105 psig. 

8.   Per UPC 609.10-

 All building water supply systems in which quick acting valves are installed shall be 

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 DRINKING FOUNTAINS

 

 

A172FGVR

Page 3 of 10

New: 

08/01/16

7020-930-001

MURDOCK  MFG.  • 

15125  Proctor  Avenue  •  City  of  Industry,  CA  91746  USA 

Phone  800-453-7465  or  626-333-2543  •  Fax  626-855-4860  •  www.murdockmfg.com

Member of

18

1
2

"

*33

1
2

"

1

3
8

"

10

5
8

"

TAILPIECE

*22

1
4

"

2

1
4

"

*25"

14

1
4

"

5"

19

3
8

"

7

7
8

"

6

5
8

"

AIR FLOW

*16"

18

5
8

"

8

1
4

"

37

1

8

"

D

E

C

B

A

4

1
4

"

7

1
2

"

14

1
4

"

A172400FGVR Wall Mounted Drinking Fountain- Reverse Bi-Level 

Summary of Contents for A172-FG-VR-WF1

Page 1: ...cover installation or labor charges and does not apply to materials which have been damaged by other causes such as mishandling or improper care or abnormal use The repair or replacement of the defective materials shall constitute the sole remedy of the Buyer and the sole remedy of Murdock under this warranty Murdock shall not be liable under any circumstances for incidental consequential or direc...

Page 2: ... 333 2543 Fax 626 855 4860 www murdockmfg com Member of I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S DRINKING FOUNTAINS GENERAL NOTES 1 ALL DIMENSIONS ARE IN INCHES MM 2 ALLOW 4 INCHES 102 MM MINIMUM CLEARANCE PER SIDE FOR VENTILATION 3 DIMENSIONS SHOWN ARE FOR RECOMMENDED ADULT HE...

Page 3: ...ult 5 All burrs must be removed from outside of cut tubes before inserting into coupler or other components 6 Warranty is voided if installation is not made following current Acorn Engineering installation instructions and if components are assembled to the fixture that is not approved by Acorn Engineering 7 Fixture operates within water pressure range of 20 to 105 psig Acorn Engineering will not ...

Page 4: ...g access panel to drinking fountain but after thoroughly flushing the supply line and connecting it to the fixture turn on building water supply and check all connections for leaks 2 Air within the drinking fountain system or the structure supply piping will cause an irregular bubbler outlet stream until purged out by incoming water Covering the bubbler with a clean cup or similar object is recomm...

Page 5: ... fully seated onto button 7 Reinstall strainer 4 and plug 3 using maintenance tool 5 NOTE STRAINER FILTER SCREEN MUST BE IN PLACE FOR WATER TO FLOW ITEM PART NUMBER DESCRIPTION 1 7003 095 001 VALVE ASSEMBLY 2 7000 060 000 FLOW REGULATOR CARTRIDGE 0 5 GPM 3 7003 097 001 O RING STRAINER PLUG 4 7003 864 000 STRAINER FILTER SCREEN 5 7003 194 199 VR MAINTENANCE TOOL 6 7003 197 199 VR PUSHBUTTON ESCUTCH...

Page 6: ...kmfg com Member of ITEM PART NUMBER DESCRIPTION 1 7012 311 000 WF1 Filter 1500 Gal 2 1895 709 000 Elbow Push in 1 4 O D x 1 4 Stem 3 2169 000 000 1 4 O D LLDPE Tubing Blue 4 7012 055 000 Foam Pipe Insullation 5 7003 670 001 Filter Assembly FG FILTER MOUNTING DETAIL LINE TO DRINKING FOUNTAIN INLET INSTALLED FILTER DETAIL NOTES 1 CUT AND DEBURR WATER LINE TUBING AS REQUIRED 2 ENSURE TUBING END IS NO...

Page 7: ...the cartridge turning clockwise to secure 5 Re insert the water filter into the water filter bracket assembly 6 Turn water inlet 1 4 turn knob 1 4 turn counterclockwise to open and test for leaks and proper operation before closing access panel I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T ...

Page 8: ...in fitting TO CUT TUBE Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET I N S TA L L AT I O N M A I N ...

Page 9: ...RINKING FOUNTAINS A172FGVR Page 9 of 10 New 08 01 16 7020 930 001 MURDOCK MFG 15125 Proctor Avenue City of Industry CA 91746 USA Phone 800 453 7465 or 626 333 2543 Fax 626 855 4860 www murdockmfg com Member of COOLER PARTS BREAKDOWN Universal Maintenance Tool Button Removal Cartridge Retaining Nut Strainer Plug Removal of P E Tubing from Push in Fittings 16 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 ...

Page 10: ... Center Reject Allen Flat head Screw 6 7003 635 199 FG VR Hanger Bracket 7 7003 681 299 Access Plate VR Auto Stop 8 7000 006 000 Flat Drain Adapter Gasket 9 7000 005 199 Drain Adapter 10 7000 019 001 1 1 4 Tailpiece Assembly 11 7003 073 000 11 4 x 1 1 2 Compression 45 Elbow 12 1758 043 299 1 1 2 O D x 3 Long Drain Tube 13 7003 072 000 1 1 2 x 1 1 2 Compression 45 Elbow 14 1758 043 199 1 1 2 O D x ...

Reviews: