3. Cartridge replacement - insert diamond end of the universal tool into push button, rotate 90 degrees
and pull firmly to remove the button. Remove cartridge retaining nut . Remove and replace cartridge.
When replacing cartridge be sure to align the inlet and outlet ports on the cartridge with the ports in
the valve body.
2. Clean strainer as needed using clean water.
Note: Use the universal maintenance tool to perform the following:
A172.8-UG-D1-BFS CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE
1. Strainer plug must be removed before cartridge replacement and strainer
maintenance (no need to turn the water off at the angle stop). Some residual water will drain
during plug removal.
—
NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.
2
4
3
1
5
ITEM
PART NUMBER
DESCRIPTION
5
7003-830-000
UNIVERSAL MAINTANANCE TOOL
4
7003-864-000
STRAINER FILTER SCREEN
3
7003-097-001
O-RING &STRAINER PLUG
2
7000-060-000
FLOW REGULATOR CARTRIDGE(05 GPMG)
1
7003-095-001
VALVE ASSEMBLY
A172.8-UG-VR-D1-BFS
Page 9 of 17
Revised:
02/10/2021
7020-986-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS