7. Use supplied flexible hose and clamps to connect waste tailpiece from the upper unit to the waste tailpiece of
lower unit and then make up 1-1/4” O.D. p-trap waste connection. Waste p-trap by others.
6. Thoroughly flush the 3/8” O.D. supply line and then connect water cooler to water supply angle stop valve (by
others) with supplied 3/8” O.D. copper tube.
5. Outlet tube from Evaporator has an in-line tee with a tube going to the refrigerated unit's valve and the "TEE"
not connected. Connect the loose Supply Tube from refrigerated unit to the "TEE".
INSTALLATION:
Choose configuration; Remove and reinstall filler plate, item 10 and reverse drain assembly if
required for alternate mounting configuration.
2. Remove the Bottom Cover from the Water Cooler and set aside in a safe place. Save the screws in a secure
location for re-use in later stages of installation.
4. Anchor the Water Coolers to the wall at the lower mounting points in each back panel. Shim lower mounting
points to level unit if necessary.
3.
Hang the Water Coolers on the hanger brackets ensuring the bracket tabs engage
AND
seat in the slots in the
back of the Water Coolers.
NOTE:
Hanging of refrigerated unit first is recommended since it is the heavier of
the two. Verify Water Coolers are level, left to right AND front to back from bottom of unit.
CAUTION:
The
Bubbler stream may be adversely affected if units are not square and level. Bottom of units and louvers
should be used as reference to verify unit is square and plumb.
1. Mount Hanger Brackets to wall horizontally level as shown in Roughing-In and Dimensional
Drawing.
NOTE:
Adjust height of Bracket if Bubbler outlet height is required to vary from that shown
/indicated. Hanger Brackets
MUST
be securely anchored to wall with fasteners sufficient to support
3 times the weight of Water Cooler.
NOTE:
If wall cannot provide adequate support, order and install optional Fixture Support Carrier.
NOTE:
If replacing a
competitors Water Cooler
you may be able to use existing mounting bracket
STANDARD WASTE CONFIGURATION
ALTERNATE WASTE CONFIGURATION
ITEM 10
FILLER PLATE
ITEM 10
FILLER PLATE
A172.8-UG-VR-D1-BFS
Page 4 of 17
Revised:
02/10/21
7020-986-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S