I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

CONTEMPORARY WATER COOLERS

 

I N S TA L L AT I O N / M A I N T E N A N C E  I N S T R U C T I O N S

 WATER COOLERS

 

7020-904-001

PRIOR TO INSTALLATION:

Important: Some options may slightly alter installation. To ensure proper installation, review the Manual 
thoroughly and verify rough-ins before beginning work. Leave this Manual with the owner or 
maintenance personnel upon completion of installation.

 Fixture mounting requirements: Industry standard wall construction, adequate to support the fixture 

and installer-provided Wall Anchors sufficient to secure the fixture.

 Receptacle(s) must be wired to a GFCI protected circuit. Fixture must be earth grounded per NEC 

(National Electric Code).

 Inspect fixture and all parts for damage.

To avoid a hazard due to instability, fixture must be installed in accordance with the instructions.

IMPORTANT:

2.   Provide 4” minimum clear space on fixture sides to allow for proper ventilation through Cabinet 

Louvers.

3.   Water Supply Inlet is 3/8” Outer Diameter copper Tubing. Waste Outlet is 1-1/4” Outer Diameter. 

4.   Completely flush supply lines of all foreign debris before connecting to fixture. Water Cooler is 

designed to not cause problems with taste, odor, color, or sediment. Optional (-WF1) Water Filter is 
available should any of these problems arise from the Water Supply. 

5.   Do NOT solder Tubing inserted into the Coupler as damage to the O-Ring may result.

1.   Waste P-Trap, Water Supply Service Angle Stop Valve, and 2” x 4” Electrical Plug-In Receptacle to 

be supplied by others in accordance with local codes. A metallic P-Trap (by others) must be used for 
the Drain connection.

10. Fixture is to operate within a water pressure range of 25 PSIG (172 kPa) to 105 PSIG (724 kPa). 

Warranty is void if the unit is allowed to operate outside the range of 25 PSIG (172 kPa) to 105 
PSIG (724 kPa). A Pressure Regulator must be installed by others on supply line if inlet pressure is 
greater than 105 PSIG (724 kPa). 

9.   Warranty is voided if installation is not followed per current Murdock Mfg. installation instructions 

and if components are assembled to the fixture that are not approved by Murdock Mfg. 

6.   All burrs must be removed from outside of cut Tubing before inserting into Coupler or other 

components. 

8.   This unit must be grounded per the requirements of applicable electrical codes. 

11. Due to cold waste water, Murdock Mfg. recommends that P-Trap supplied by installer be insulated 

to prevent excessive condensation. 

12. 

609.10 Water Hammer

. Building water supply systems where quick-acting valves are installed shall 

be provided with water hammer arrester(s) to absorb high pressures resulting from the quick closing 
of these valves. Water hammer arresters shall be approved mechanical devices that comply with 
ASSE 1010 or PDI-WH 201 and shall be installed as close as possible to quick-acting valves.

7.   Power Supply must be identical in voltage, cycle and phase to that specified on the Water Cooler 

Data Plate. Electrical Outlet and furnished Power Cord with Plug must be used to supply power to 
fixture. Do NOT wire Compressor directly to the Power Supply. 

 

Summary of Contents for A171 Series

Page 1: ...he compressor and hermetically sealed refrigeration system including cooling coil assembly when part of the hermetically sealed refrigeration system to be free from defects in material and workmanship under normal use for an additional four 4 years from the end of the one 1 year period described above This warranty does not cover installation or labor charges and does not apply to materials which ...

Page 2: ...r away from it Every attempt should be made to prevent this kind of grounding from generating electrical feedback into the Water Cooler creating electrolysis Electrolysis will cause a metallic taste or cause water metal content to increase NOTICE ROUGHING IN AND DIMENSIONAL DRAWING NOTES Dimensions indicated are for ADA frontal approach installation Adjust vertical dimension as required to comply ...

Page 3: ...older Tubing inserted into the Coupler as damage to the O Ring may result 1 Waste P Trap Water Supply Service Angle Stop Valve and 2 x 4 Electrical Plug In Receptacle to be supplied by others in accordance with local codes A metallic P Trap by others must be used for the Drain connection 10 Fixture is to operate within a water pressure range of 25 PSIG 172 kPa to 105 PSIG 724 kPa Warranty is void ...

Page 4: ... the slots in the back of the Water Cooler Verify Water Cooler is level left to right AND front to back from bottom of unit NOTE The Bubbler stream may be adversely affected if unit is not square and level Bottom of unit and Louvers should be used as reference to verify unit is square and plumb INSTALLATION START UP 6 Make up 1 1 4 O D P Trap by others waste connection 1 Before connecting Power Su...

Page 5: ...0 000 TUBING LLDPE BLUE 1 4 OD 5 3 7012 311 000 WF1 FILTER 1500 GALLON 1 ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE BLUE 1 4 OD 5 NON PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH FILTER WITHOUT GF BF OPTIONS 1 Starting from the wall connection connect to the inlet of the Water Filter 2 From the outlet of the Water Filte...

Page 6: ... N S T R U C T I O N S CONTEMPORARY WATER COOLERS I N S TA L L AT I O N M A I N T E N A N C E I N S T R U C T I O N S WATER COOLERS 7020 904 001 PRESSURIZED SINGLE UNIT PIPE INSTALLATION WITH GF BF OPTIONS ITEM PART NUMBER DESCRIPTION QTY 1 7012 055 000 FOAM INSULATION PIPE 3 8 ID x 1 4 THICK 5 5 2 2169 000 000 TUBING LLDPE BLUE 1 4 OD 5 17 Water Supply Tubing 13 Water Supply Tubing 1 2 To BF Bott...

Page 7: ...o move the water supply Tubing around with NO additional Tubing needed Before performing this task you MUST SHUT OFF THE WATER SUPPLY and disconnect all supply connections STEP 3 From the outlet of the Cartridge assembly connect to the Bubbler STEP 1 Starting with the supply line coming from the wall connect to the inlet of the Evaporator assembly STEP 2 From the outlet of the Evaporator assembly ...

Page 8: ...r Thermostat The water temperature can be adjusted using a slotted Screwdriver and turning clockwise to make colder and counterclockwise to make warmer c Bubbler Stream Bubbler can be rotated slightly to direct the stream backwards or forwards Adjust the stream to minimize splashing Splashing may occur from Bubbler stream if the unit is not level Shim lower mounting points if necessary to level Wa...

Page 9: ...tore electrical power if no damage is found 5 Noisy Operation a Check to make sure the Fan Blade is rotating freely b Make sure the Water Cooler is correctly mounted to the wall Absence of the two lower mounting bolts may cause excess noise and vibration c Check the Compressor mounting to make sure the Pins and Clips are not rattling If the Compressor appears to be noisy internally it must be repl...

Page 10: ...es and pull firmly to remove the Button Remove Cartridge Retaining Nut Remove and replace Cartridge When replacing Cartridge be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body Note Use the Universal Maintenance Tool to perform the following NOTE STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW 1 Strainer Plug must be removed before Cartridge replacement...

Page 11: ...uld not come free from the Fitting Water test the Connection assembly prior to leaving the site to ensure there are no leaks DISCONNECTING THE TUBE To disconnect the tube from the Fitting ensure that the water line is depressurized Push Collet square towards the Push In Fitting Body and hold While holding the Collet in pull on the plastic PE Tubing to remove from the Push In Fitting TO CUT TUBE Cu...

Page 12: ...O N S WATER COOLERS 7020 904 001 Standard A171 8 series refrigerated ADA Water Cooler shown All 1 4 O D Plastic Tubing 24 must be insulated with 25 foam insulation NOTE See next page for table of part numbers corresponding to drawing above WATER COOLER PARTS BREAKDOWN Universal Maintenance Tool Pushbutton Removal Removal of P E Tubing from Cartridge Retaining Nut Strainer Plug Push in Fittings 27 ...

Page 13: ... 0124 032 000 8 x3 4 LG PHIL FLAT HD SELF TAPPING SCREW 4 7000 006 000 FLAT DRAIN GASKET 5 7003 180 000 DRAIN TAILPIECE 6 7003 003 199 BACK PANEL 7 7003 007 199 SUPPORT STRUT 8 7003 250 000 COLD CONTROL 7003 210 020 APRON ASSEMBLY GRANITE 7003 211 002 APRON ASSEMBY STAINLESS STEEL 10 7003 095 001 VALVE ASSEMBLY 11 7003 099 000 PUSHBUTTON 7003 004 020 COVER GRANITE 7003 035 299 COVER STAINLESS STEE...

Reviews: