I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
WATER COOLERS
7020-904-001
A Dielectric Coupling must be used to connect the Water Cooler to the water supply. A nonmetallic Coupler
is furnished with this Water Cooler to meet this requirement.
Prior to roughing-in, consult with local, state, and federal codes for proper mounting height. All installation
and service may only be performed by authorized personnel. No unauthorized persons shall have access to
the service area.
IMPORTANT
This Fixture is intended for indoor use only and is not suitable for installation in an area where a water jet
could be used as well as in environments where freezing may occur. This fixture dispenses water that has
been lowered in temperature, but otherwise remains unchanged by the materials in the W ater Cooler. It is
common for electrical equipment to be grounded to water lines either within a structure or away from it.
Every attempt should be made to prevent this kind of grounding from generating electrical feedback into the
Water Cooler creating electrolysis. Electrolysis will cause a metallic taste or cause water metal content to
increase.
NOTICE
ROUGHING-IN AND DIMENSIONAL DRAWING
NOTES:
Dimensions indicated (*) are for ADA frontal approach installation. Adjust vertical dimension (*)
as required to comply with federal, state, and local codes. For Child ADA compliant parallel approach,
decrease Bubbler spout height to 30” maximum above finished floor. Provide clear floor space as
required.
7
1
4
"
[184]
2
3
4
"
[70]
18
1
2
"
[470]
4
1
4
"
[108]
1
3
8
"
[35]
4
5
8
"
[117]
12"
[305]
TAIL
PIECE
*33"
[838]
6
1
2
"
[165]
7
7
8
"
[200]
*22"
[559]
5
1
4
"
[133]
A. 3/8" OD Supply Inlet
B. Waste Outlet for 1-1/4" P-Trap by others
C. Electrical Service Rough-In
D. Ø3/8" Hanger Bracket punching, 3 places
for Anchoring Hardware by others
E. Ø1/4" punching, 2 places for Anchoring
Hardware by others
A
B
C
E
D
19
3
8
"
[492]
7
1
4
"
[184]
*15
5
8
"
[397]
13
1
2
"
[343]
18
1
2
"
[470]
*16
3
8
"
[416]
2
1
4
"
[57]
4
1
4
"
[108]
6
5
8
"
[168]
General Notes:
1.
All Dimensions are in Inches [MM]
2.
Allow 4 inches [102 MM] minimum clearance per side for ventilation
3.
Dimensions shown are for ADA adult height. Adjust vertical dimensions
as necessary to comply with Federal, State, & Local Codes
4.
Stop Valve, P-Trap, & Electrical Outlet not supplied
5.
Important: Water Coolers must be attached to wall with appropriate
Anchor Screws