A151.8-VR
Page 9 of 11
Date:
11/10/2020
7021-024-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
CONTEMPORARY WATER COOLERS
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAINS
CARTRIDGE VALVE PARTS BREAKDOWN
3
2
1
5
4
Note: Use the Universal Maintenance Tool to perform the following:
CARTRIDGE REPLACEMENT/ STRAINER MAINTENANCE
3. Cartridge Replacement - insert diamond end of the Universal Tool into Pushbutton, rotate 90 degrees and pull
firmly to remove the Button. Remove Cartridge Retaining Nut . Remove and replace Cartridge. When replacing
Cartridge, be sure to align the inlet and outlet Ports on the Cartridge with the Ports in the Valve Body.
—
NOTE: STRAINER SCREEN MUST BE IN PLACE FOR WATER TO FLOW.
1. Strainer Plug must be removed before Cartridge replacement and Strainer maintenance (no need to turn the
water off at the Angle Stop). Some residual water will drainduring Plug removal.
2. Clean Strainer as needed using clean water.
-Removal of P.E. Tubing from
Universal Maintenance Tool
-Button Removal
-Cartridge Retaining Nut
-Strainer Plug
Push-in Fittings
6
ITEM #
PART NUMBER DESCRIPTION
1
7003-095-000
Valve Body Sub Assembly
2
7000-060-000
Valve Cartridge
3
7000-052-000
Retaining Nut
4
7003-864-000
Strainer, Auto Stop
5
7003-097-001
Strainer Cap
6
7003-194-199
Maintenance Tool