Murata N1-2657 Quick Start Manual Download Page 2

N1-2657: TypeZF Mother Board Quick-Start Guide 

 

2 / 4 

 

 

 

3.  Hardware description 

3.1.  Hardware description 

 

 

Figure 2 Overview of the Mother Board 

 
 

Table 1 Jumpers of the Mother Board 

Name 

Function 

Description 

Default 

Settings 

Photo 

3V3 

Output 

Regulated  3.0V  output  generated  internally 
by Mother Board.   

Tied 

 

EXT 

Input 

Input  for  the 

Current  Measurement

  circuit 

block.   
(should  be  connected  to  3V3  pin  directly  or 
external power supply) 

MOD 

Output 

Output  from  the 

Current  Measurement

 

circuit block. 

Tied 

VBAT 

Input 

Power input for Daughter Board 

GND 

Ground 

Ground 

 

VPP_EXT 

Input 

Power  input  for  External  VPP  (only  used 
when VPP is supplied externally.) 

Open 

GND 

Ground 

Ground 

 

EN_ADBUS0 

Jumper 

Should be tied to enable RXD/CK 

Tied 

 

EN_ADBUS1 

Jumper 

Should be tied to enable TXD/DI 

Tied 

EN_ADBUS2 

Jumper 

Should be tied to enable CTS/WAKE/DO 

Tied 

EN_ADBUS3 

Jumper 

Should be tied to enable RTS/RDY/CS 

Tied 

EN_ADBUS5 

Jumper 

Should be tied to enable DTR/INT 

Tied 

SEL_VPP 

Jumper 

Select  VPP  source,  internal  or  external 
(VPP_EXT) 

Select “INT” 

 

AD_TRIG 

Input 

TBD. Can be left open if not used.   

Open 

 

 

 

 

Jumper 

Should be tied to enable input of the 

Current 

Measurement

 circuit block.   

Tied 

 

EN_MEAS- 

Jumper 

Should  be  tied  to  enable  output  of  the 

Current Measurement

 circuit block.   

Tied 

JL_VCC_SEL 

Jumper 

Select  J-Link  VCC  source.  Should  be  tied 
center  pin  and  either  of  “BUCK”  /  ”BOOST” 
depends on the Daughter Board schematics. 

Select 
“BUCK” 

 

 

 

 

 