6
2) Confirm the proper mounting direction before installing the sensor.
JPN
M
Clockwise
Positive v)
03JA
822
Counter clockwis
Negative voltage(
Sensing axis
3) Bias and scale factor drift
Surrounding temperature variation may affect the sensor output (bias, scale factor). Sensor
should be mounted where temperature does not vary significantly.
When canceling bias drift, please refer to the following examples.
- Cut DC level along output by using a HPF (Hi-Pass-Filter) with a low cut-off frequency on the
sensor output. ( Refer to page 7)
9. Handling
1) Incorrect handling may affect the sensor characteristics. Please note the following precautions;
A. Do not subject the sensor to shocks which exceed the rated limit.
Typically, the sensor can withstand shock peak to 500G, duration 1msec, half sine wave.
B. Do not install or store the sensor in a location where condensation is likely to form on it.
C. Do not install or store the sensor in a location where water may splash directly on it.
D. Do not install or store the sensor in a location in which it is likely to be exposed to salt water or
corrosive vapor.
2) Precision electronic parts, such as ICs, are used for the sensor; therefore, it is necessary to take
anti-static precautions when handling.
3) Do not wash the sensor, as it is not water resistant.
4) Do not disassemble.