Muonio UV-L 110 Installation Manual Download Page 9

PAGE 9

f

astenings

 

are

 not 

supplied

 

because

 

the

 

options

 

are

 

too

 

varied

 

to

 

ensure

 

optiMal

 

fixing

 

strength

p

lease

 

do

 

not

 

install

 

the

 

unit

 

in

 

locations

 

where

 

it

 

can

 

be

 

detriMentally

 

affected

 

by

 

accuMulations

 

of

 

dirt

grease

condensation

or

 

other

 

daMaging

 

substances

.

d

o

 

not

 

cover

 

or

 

obstruct

 

the

 

air

 

inlet

 

or

 

outlet

 

grille

.

e

nsure

 

the

 

appliance

 

is

 

earthed

.

d

o

 

not

 

use

 

this

 Muonio uv-l 110 

in

 

areas

 

where

 

excessive

 

dust

 

exists

.

a

lways

 

disconnect

 

supply

 

before

 

working

 

on

 

the

 

product

.

b

efore

 

installation

: r

eMove

 

the

 

retaining

 

screws

 

and

 

the

 

cover

install

 

the

 uv-c 

bulbs

 (

delivered

 

in

 

protec

-

tive

 

packaging

inside

 

the

 

unit

), 

and

 

replace

 

the

 

cover

 

and

 

retaining

 

screws

t

his

 

product

 

should

 

be

 

Mounted

 

safely

 

to

 

solid

 

wall

 

or

 

ceiling

 

surfaces

 

only

.

w

arning

do

 

not

 

Mount

 

the

 

unit

 

vertically

s

olid

 

brick

 

or

 

concrete

 

block

 

walls

 

Must

 

be

 

drilled

 

(

using

 

a

 

spirit

 

level

 

as

 

a

 

guide

 

to

 

ensure

 

bracket

 

is

 

level

and

 

plugs

 

with

 

rawlplugs

 

not

 

supplied

. t

he

 

plug

 

and

 

screw

 

fastenings

 

Must

 

be

 

located

 

in

 

the

 

solid

 

part

 

of

 

the

 

wall

not

 

just

 

in

 

the

 

plaster

 

layer

.

f

or

 

panelled

 

internal

 

walls

 

or

 

ceilings

it

 

is

 

best

 

to

 

locate

 

the

 

studding

position

 

the

 

heater

 

fixing

 

bracket

 

accordingly

.

Mounting The Unit on Walls or Ceilings

Bracket Dimensions

FIG 6

WALL BRACKET

39

MM

78

MM

39

MM

94

MM

Ø8

MM

, SECURING

SCREW HOLE
X  5

MM

, SCREWS

OPTIONAL
CABLE ENTRY POINT

 

INSTALLING THE UNIT

EXAMPLE
BRACKET FIXINGS

Choosing the correct fastening method to fix the unit securely 
to the selected wall or ceiling for the particular job is critically 

important to secure the public’s safety and protect the equipment.

FIG 3

FIG 5

FIG 4

Summary of Contents for UV-L 110

Page 1: ...blic places or other spaces at a very eco nomical cost The unit uses well established UV C radiation which was utilised extensively in medical food preparation and other professions for more than 40 years to disinfect the air the cleanliness of the surfaces and to help mitigate the risk of contracting and spreading an infec tion All bacteria and viruses tested to date including various coronavirus...

Page 2: ...nd Line of Sight 8 Installing the Unit Mounting The Unit on Walls or Ceilings 9 Bracket Dimensions 9 General layout Installation Procedure 10 Terminal Identification Description INSTALLATION WIRING 11 Earth Connection 11 Double Pole Isolation 11 Control Module Connections 11 Power Supply 11 Volt free SWITCHING CONTROL 11 OPTIONAL SWITCH LIVE CONTROL 11 Service Commissioning SERVICE MAINTENANCE 12 ...

Page 3: ... and microbial compounds including the multi drug resistant strains confirmed a highly effi cient reduction in the number of microorganisms in the testing area The MUONIO UV L 110 UVC radiation unit conformed to the standard showing a significant decrease in the total number of Mesophilic bacteria and the total number of Moulds with a minimum of 2 logarithms to the air s total number of microorgan...

Page 4: ...ated via app remote control or directly on the device 2 variants Technical Information MUONIO UV L 110 Terminals 0 5 Mm2 To 1 5 Mm2 Dimensions Cca 169 X 171 X 1158Mm Mountable Bracket Horizontal Or Vertical Weight Cca 12 5 Kg Fused Power Supply 230 Vac 50 Hz Single Phase Power Supply 0 41 A Fuse 5 Amp Medium Bur Wireless Frequency 2 4 Ghz With External Antenna only for App controlled device Enclos...

Page 5: ...ow this symbol to avoid possible injury or death CAUTION indicates a hazardous situation which if not avoided could result in minor or moderate injury DANGER indicates a hazardous situation which if not avoided will result in death or serious injury IMPORTANT Disregard will lead to permanent equipment damage When in operation the product will emit internal UV C radiation UV C radiation is invisibl...

Page 6: ... the unit periodically check the security of mounting Disconnect the unit from power supply prior to investigating any technical maintenance issue Remove the UV C bulbs if the power supply is required when fault finding the fan or any other component This Manual covers the installation of the UV C fan operated MUONIO UV C Disinfectant Unit Type One UV L 110 MAN The Unit requires a 230 Vac power su...

Page 7: ... with the Product and consult it regularly MUONIO UV L 110 product contains components that emit UV C light sealed safely inside the metal enclosure and poses no danger to health in its enclosed state when installed correctly according to these installa tion instructions Failure to follow the warnings in this publication and any other safety guideline regarding the installation or uses of UV C pro...

Page 8: ...s effectiveness depends on the airflow efficiency rate over time This positioning location creates an area that disinfects any air containing droplets or viruses or bacteria passing through the region or deactivates anything circulating into that upper portion of the room with UV C light The Unit protects the occupants by combining upward facing louvres at both ends combined with secondary inward ...

Page 9: ...safely to solid wall or ceiling surfaces only Warning do not mount the unit vertically Solid brick or concrete block walls must be drilled using a spirit level as a guide to ensure bracket is level and plugs with rawlplugs not supplied The plug and screw fastenings must be located in the solid part of the wall not just in the plaster layer For panelled internal walls or ceilings it is best to loca...

Page 10: ...illing the wire entry hole 7 Ensure that the unit is secured to the mounting bracket using both locking screws provided on each side to fix it at the final selected angle position 8 Use the mounting bracket to mark the mounting hole centres on the selected wall or ceiling allowing if necessary for the electric cables to pass through the cable entry hole in the centre of the bracket 9 We would reco...

Page 11: ...cable entry point at the top of the unit The power supply should be connected to N_in Neutral Blue and L_in Live Brown The E Earth Green Yellow must be connected to ground Volt free SWITCHING CONTROL If UV C ventilator is to be operated manually then an external switch must be installed across the Volt Free terminal connections The unit will operate if the volt free terminals make contact through ...

Page 12: ...actice to replace the lamps once every year In normal circumstances UV C lamp service life is around 9000 hours or running permanently for 1 Year but other factors such as re starts and elements erosion of fillers in the UVC lamp can also affect the quality of output over time Dust can also decrease the lamp s disinfectant efficiency Exercise extreme caution when cleaning the Unit or disposing of ...

Page 13: ...TINGS BY THE USER OR ANY DAMAGE RESULTED AS FROM SUCH CHANGES THIS WARRANTY SHALL BE VOID IF UV LAMPS FROM MANUFACTURER S OTHER THAN MOUNIO ARE USED WITH THIS EQUIPMENT DAMAGE TO NEW ALL MOUNIO PRODUCTS MUST BE EXAMINED ON RECEIPT PLEASE EXAMINE ALL UNITS AND PACKAGING ANY CLAIMS IN RESPECT TO THE DELIVERED PRODUCTS INCLUDING VISIBLE DEFECTS QUANTITY SHORTAGES OR INCORRECT PRODUCT SHIPMENTS MUST B...

Page 14: ...centres Avoid hazards to the environ mentanddangerstoyourpersonalhealthbydisposingofthedeviceproperly Forfurtherinformationaboutproper disposal contactyourlocalcouncil wastedisposalofficeortheshopwhereyouboughtthedevice WWW MUONIO ME info nrgawareness com Local Agent AWARENESS CONTACT DETAILS CUSTOMER SIGNATURE_____________________________ DATE________________SERIALNUMBER _________________ WARRANT...

Reviews: