2. Define:
o
The operation mode.
o
Humidity to Stop: Define the humidity level at which cooling stops.
o
Humidity Band: Set the humidity band to re-enable cooling outputs after it the process
ceases because of the high humidity level.
o
Filling Time: Define the amount of time required to distribute water over the pad.
o
Cooling Enabled: Define when cooling is enabled, 24 hours a day or time frames.
3. Go to Climate > Cooling. The screen that appears depends on the operation mode chosen.