background image

 

HER Air Heaters 

 

© Munters Europe AB, 2009

 

Munters reserves the right to make alterations to specifications, quantities, etc. for production or other reasons, subsequent to publication

.

 

Page 13 of 14 

 

8. Wiring diagrams  

 
 

HER 100/130/160 1-PH 

 

 

HER 100/130/160 3-PH 

 

HER 220 1-PH 

 

HER 220 3-PH 

 

 

 

                                                           

ROOM THERMOSTAT WIRING 

 

 
 

 

 

 
 
 
 

Summary of Contents for HER 100 C

Page 1: ...Manuale d uso Instruction manual Generatori di aria calda Air heaters HER 100 HER 130 HER 160 HER 220 HER 100 HER 130 HER 160 HER 220 ...

Page 2: ...ale infiammabile La temperatura ambiente di funzionamento dell apparecchio deve essere compresa tra 20 C e 40 C in modalità riscaldamento o tra 20 C e 50 C in modalità ventilazione Rispettare le leggi e le norme sulla sicurezza del lavoro e sulla protezione dagli infortuni vigenti nei rispettivi settori di impiego L apparecchio contiene parti in movimento e parti sotto tensione Utilizzare l appare...

Page 3: ...ttrica di alimentazione con terra facendo riferimento allo schema elettrico e alla tensione di targa della macchina vedi par 8 Utilizzare un cavo di alimentazione di sezione opportuna in funzione della corrente di targa Il collegamento alla rete deve essere effettuato esclusivamente da personale qualificato nel rispetto delle norme di sicurezza elettrica vigenti Nella rete di alimentazione deve es...

Page 4: ...egolazione L apparecchio è dotato di un pulsante spia di riarmo manuale che si trova sul pannello frontale del bruciatore Quando l apparecchio va in blocco la spia rossa si illumina In questo caso dopo aver cercato ed eliminato la causa del blocco premere il pulsante di RESET per riavvare l apparecchio vedi anche il paragrafo Soluzione dei problemi L apparecchio è dotato anche di un termostato di ...

Page 5: ...ciatorista autorizzato Seguire anche le disposizioni legislative in vigore nel Paese di utilizzazione dell apparecchio 5 Guida alla soluzione dei problemi Problema Causa Soluzione L apparecchio non parte Mancanza tensione Tensione sbagliata Termostato ambiente regolato troppo basso Cappuccio presa termostato non inserito Intervento precedente del termostato di sicurezza Blocco bruciatore precedent...

Page 6: ... 100 Diesel Riello RGF2 Danfoss 2 00 GPH 600S 12 6 3 3 mm 6 52 5 mm 0 Metano G20 Riello FS10 4 5 4 4 4 0 Propano G31 Riello FS10 6 3 4 4 8 0 HER 130 Diesel Riello RG3 Danfoss 2 50 GPH 600S 12 4 5 8 5 mm 3 1 38 2 mm 0 Metano G20 Riello FS15 3 5 2 3 0 Propano G31 Riello FS15 4 7 2 3 25 0 HER 160 Diesel Riello RG3 Danfoss 3 00 GPH 600S 12 6 4 9 mm 3 05 40 mm 0 Metano G20 Riello FS15 4 3 3 5 0 Propano...

Page 7: ...ves the right to make alterations to specifications quantities etc for production or other reasons subsequent to publication Page 7 of 14 8 Schemi elettrici HER 100 130 160 1 PH HER 100 130 160 3 PH HER 220 1 PH HER 220 3 PH CABLAGGIO TERMOSTATO AMBIENTE ...

Page 8: ...verheat of floors walls and ceilings made of flammable materials The operational temperature must be in the range between 20 C and 40 C for heating mode or between 20 C and 50 C for ventilation mode Follow the health and safety at work regulations and standards in force in the different fields of application The heater contains moving parts and live parts Use the heater only when all parts of the ...

Page 9: ...Electrical supply Connect the unit to an earthed electrical supply following the wiring diagram see par 7 and the rated voltage see data plate Use a power supply cable of proper type and size based on the heater current rating All electrical connections must be carried out by qualified personnel only complying with the electrical safety standards in force A circuit breaker with minimum 3 mm distan...

Page 10: ...et pushbutton lamp on the burner front panel If the heater locks out the red lamp lights up In this case after eliminating the cause of lock out push the reset button to restart the heater see also par Troubleshooting The heater is equipped with a manually reset safety thermostat with fixed setting that prevents the unit from overheating In the event that the safety thermostat trips disconnect the...

Page 11: ...ter season by an authorized burner technician is recommended Also follow the local and national regulations in force 5 Troubleshooting Problem Cause Solution The heater does not start No power Incorrect voltage Too low room thermostat setting Thermostat cap connector not inserted Previous safety thermostat trip Previous burner lock out Check power supply system Check voltage Set higher temperature...

Page 12: ...flange position HER 100 Diesel Riello RGF2 2 00 GPH 600S 6 3 3 mm 6 52 5 mm 0 Methane G20 Riello FS10 4 5 4 4 4 0 Propane G31 Riello FS10 6 3 4 4 8 0 HER 130 Diesel Riello RG3 2 50 GPH 600S 12 4 5 8 5 mm 3 1 38 2 mm 0 Methane G20 Riello FS15 3 5 2 3 0 Propane G31 Riello FS15 4 7 2 3 25 0 HER 160 Diesel Riello RG3 3 00 GPH 600S 12 6 4 9 mm 3 05 40 mm 0 Methane G20 Riello FS15 4 3 3 5 0 Propane G31 ...

Page 13: ...serves the right to make alterations to specifications quantities etc for production or other reasons subsequent to publication Page 13 of 14 8 Wiring diagrams HER 100 130 160 1 PH HER 100 130 160 3 PH HER 220 1 PH HER 220 3 PH ROOM THERMOSTAT WIRING ...

Page 14: ...HER Air Heaters Munters Europe AB 2009 Munters reserves the right to make alterations to specifications quantities etc for production or other reasons subsequent to publication Page 14 of 14 ...

Reviews: