9. REMOVE INSULATED MALE SPADE TERMINAL FROM THE INSULATED
FEMALE SPATE ATTACHED TO THE WHITE WIRE.
10. ASSEMBLE NEW FUSE SUB ASSEMBLY. CRIMP THE NON INSULATED
FEMALE TERMINALS TO BOTH SIDES OF THE FUSE.
11. REMOVE FUSE ASSEMBLY FROM HEATER BY PULLING STRAIGHT
OUT ON THE UNINSULATED FEMALE TERMINALS.
12. REPLACE FUSABLE LINK WITH NEW FUSE SUB ASSEMBLY BY
REINSTALLING FEMALE TERMINALS TO SYSTEM TABS.
13. REPEAT STEPS 8 THROUGH 12 FOR THE SECOND REPLACEABLE
FUSE.
14. BOTH FUSE ASSEMBLIES MUST BE INSIDE THE INNER
REACTIVATION CHAMBER BEFORE REINSTALLING THE METAL MESH
FILTER.
15. REASSEMBLY: REVERSE STEPS 1 THRU 6.
Replacing Fusible Links Revision 7/11