mundoclima MVD DC2 Series Installation And User Manual Download Page 16

15

● 

V

ersion II 

    

V

ertical unit with casing. The air intake is at the bottom and the

    air outlet on top for installing on a wall or with feet on the floo

r

.

● 

V

ersion III

    The vertical unit is concealed in the wall after installation, with
    air intake from the bottom and air delivery at the top.

Air filter

(Filter the dust in the air)

Electric control box

Air outlet 

(Expels room air)

Air intake 

(Intakes room air)

Air filter 

(Filters dust)

Figure 9.2

Figure 9.3

 

 

 

 

 

 

 

 

 

   

 

   

   

 

 

   

   

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

   

 

 

   

 

 

 

 

 

   

 

   

 

   

 

 

   

 

 

 

 

 

 

 

    

 

Figure 9.1

Air out, air out louver 

(Adjust the air-out direction)

Air Intake 

(Intakes room air)

Air intake

(Intake room air here)

Air out, air out louver

(Adjust the air-out direction)

Feet (Lift up the 

air conditioner)

 

 

 

     

 

 

 

   

 

 

   

   

Do

 

not

 dispose of this product 

as

 unsort-

ed waste. It must be separately collected 
and  processed.  Ensure  that 

all

applicable  legislation  regarding  the
disposal  of  refrigerant, 

oil

  and  other

materials 

is

  adhered  to. 

Contact

  your 

local

  waste  disposal  authority  for

information about disposal procedures.

This  appliance 

is

 

not

  intended  for  use  by  persons  (including 

children) with reduced physical, sensory 

or

 mental capabilities, or 

lack of experience and knowledge, unless they have been given 
supervision 

or

 instruction concerning use of the appliance by a 

person responsible for their safety. Children should be supervised 
to ensure that they do not play with the appliance.

This  appliance 

can

  be  used  by  children  aged  from 

8

  years  and 

above  and  persons  with  reduced  physical,  sensory 

or

  mental 

capabilities 

or

 lack of experience and knowledge if they have been 

given supervision 

or

 instruction concerning use of the appliance in 

a

 safe way and understand the hazards involved. Children shall not 

play with the appliance. Cleaning and user maintenance shall not 
be made by children without supervision.

9. Part Names

The

 

figure

 

shown

 

above

 

is

 

for

 

reference

 

only

 

and

 

may

 

be

 

slightly 

different from the actual product.

Air Outlet Louver (adjustable)

For 

onsite

 

adjustment

 

to

 

three-direction

 

or

 

two-direction, 

please contact the local dealer.

 

V

ersion I

V

ertical unit with casing.

 

The air intake is on the front and

the air outlet on top for installing on a wall or with feet on the 

floo

r

.

 

To

 

av

oi

d

 

damag

in

g

 

t

h

e

 

re

m

ote

 

control

,

 

e

x

ercise

 

ca

u

tion

 

wh

en

  

u

sin

g

 

it

 

an

d

 

rep

lacin

g

 

its

 

b

atteries

.

 

Do

 

not

 

p

lace

 

ob

jects

 

on

 

to

p

 

o

f

 

it

.

 

Do

 

not

 

place

 

appliances

 

that

 

have

 

naked

 

flames

 

under

 

or

 

near

 

the

  

unit, as heat from the appliance can damage the unit.

 

Do

 

not

 

place

 

the

 

unit’s

 

remote

 

control

 

in

 

direct

 

sunlight.

 

Direct

  

sunlight can damage the remote control’s display.

 

Do

 

not

 

use

 

strong

 

chemical

 

cleaners

 

to

 

clean

 

the

 

unit,

 

as

 

doing

 

so

  

can

 

damage

 

the

 

unit’s

 

display

 

or

 

other

 

surfaces.

 

If

 

the

 

unit

 

is

 

dirty

  

or

 

dusty,

 

use

 

a

 

slightly

 

damp

 

cloth

 

with

 

very

 

diluted

 

and

 

mild

  

detergent to wipe the unit. Then, dry it with a dry cloth.

 

Children shall not play with the appliance.

Summary of Contents for MVD DC2 Series

Page 1: ...CL23460 CL23476 English Floor Standing MVD DC2 Installation and User Manual www mundoclima com MVD DC2...

Page 2: ...al shocks and fire Install at a strong and firm location which is able to withstand the equipment s weight If the strength is not enough or installation is not properly done the set will drop and caus...

Page 3: ...to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indoor unit wires You are not allow to connect the air conditioner with the power sou...

Page 4: ...ts Mounting Screw 4 All the illustrations of this manual are for explanatory purpose only The appearance functions and physical objects may differ please refer to the actual product Air outlet Air inl...

Page 5: ...r discharge piping and plastic parts 4 2 Choosing an Installation Site 1 Choose a site that fully complies with the following conditions and user requirements to install the air conditioning unit Well...

Page 6: ...ion surroundings WOOD STRUCTURE Put the square timber horizontally on the roof beam and then install the hanging bolts Timber on beam Hanging bolts Embedding bolts Sliding insert Blade shape insert St...

Page 7: ...6 5 Dimensions Liquid side E Gas side F BOLT HOLES A B 200 128 C 47 D Refrigerant pipe connection point Refrigerant pipe connection point Fig 4 11 Covered equipment...

Page 8: ...12 7 4 5 1240 495 984 375 6 4 12 7 7 1 1360 591 1104 391 9 5 15 9 5 6 1360 591 1104 391 6 4 12 7 G H 915 470 915 470 915 470 1133 470 1253 566 1253 566 200 80 H G C D 8 0 1360 591 1104 391 9 5 15 9 1...

Page 9: ...ture in during installation 4 5 1 Connecting Pipes Procedure 5 1 1 Measure the necessary length of the connecting pipe and follow the instructions 1 Connect the indoor unit first and then the outdoor...

Page 10: ...Do not damage the piping 4 6 4 Piping Installation For the installation of the outdoor unit s refrigerant pipe please refer to the installation manual provided with the outdoor unit All gas and liqui...

Page 11: ...sure all the connections in the piping system are properly sealed to prevent water leaks 5 2 Water Discharge Test Before testing make sure that the water discharge pipe is smooth and check if each con...

Page 12: ...ng with the power on Do not bind the refrigerant piping power cords and communication wiring together When the power cord and communication wiring are parallel the distance between the two lines must...

Page 13: ...terial to seal and protect the perforated wires Poor sealing may lead to condensation and entry of small animals and insects that may cause short circuits in parts of the electrical system causing the...

Page 14: ...Capacity HP number has not been set 8 Test Run 8 1 Precautions Before Test Run Indoor and outdoor units are properly installed Piping and wiring are correct No refrigerant piping system leaks Smooth...

Page 15: ...ked by dirt or dust water leaks may occur when the unit is Do not allow this unit or its remote control to come into contact Do not touch the unit or its remote control with wet hands as doing so can...

Page 16: ...o not play with the appliance This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if...

Page 17: ...l receiver Operation lamp MANUAL OPERATION TIMER DEF FAN ALARM Anti cold air defrosting indicator Check regularly Figure 11 1 Please note how you can best save energy and achieve the best cooling heat...

Page 18: ...that outlet air is either cooler or hotter than the set room temperature Avoid direct exposure to outlet air as it may be too cool or hot 2 Take out the air filter 3 Clean the air filter During the op...

Page 19: ...or up to 12 minutes under some operating conditions If the OPERATION LED on the unit s panel is lighting the system is working normally and the unit will start after the intentional delay is complete...

Page 20: ...e day The outside temperature is unusually high 19 A power cut has occurred the power of the premises has been cut off The remote control batteries are dead Arrange for a professional technician to ch...

Page 21: ...onditioner operation will stop up to the set time 20 14 3 Remote Control Troubleshooting Warning Certain troubleshooting steps that a professional technician may perform when investigating an error ar...

Page 22: ...tioned Damaged main PCB E6 E7 Indoor EEV coil error Eb Outdoor unit error Ed MS box PCB malfunction Emergency stop A0 MS self check failure U4 MS failure F8 IDU address repeat Error code display F7 an...

Page 23: ...SAT 34 93 652 53 57 www mundoclima com C N POLES 249 P1 08013 BARCELONA SPAIN 34 93 446 27 80...

Reviews: