background image

 

English

    

MVD

www.mundoclima.com

Installation and owner's manual

MINI MVD V6M OUTDOOR UNIT

and information requirements

CL23274 to CL23275

MVD-V280W/DGN1
MVD-V335W/DGN1

Summary of Contents for MINI MVD V6M

Page 1: ...English MVD www mundoclima com Installation and owner s manual MINI MVD V6M OUTDOOR UNIT and information requirements CL23274 to CL23275 MVD V280W DGN1 MVD V335W DGN1...

Page 2: ...d use This unit must be installed by a professional according RD 795 2010 RD 1027 2007 and RD 238 2013 The power supply must be SINGLE PHASE one phase L and one neutral N with his grounded power GND s...

Page 3: ...ly if there are possible damage Do not install in a place that might increase the vibration of the unit To avoid personal injury with sharp edges be careful when handling parts Perform installation wo...

Page 4: ...of the conventional refrigerant take out the flare nut attached to the main unit of the air conditioner and use it Before installation Be careful to the following items before installation Air purge...

Page 5: ...or unit power cord and connecting wire at least 1m away from TV set or radio to prevent noise or picture interference Strong wind Strong wind 3 2 Installation space Unit mm 300 600 300 0 0 0 3 Wall or...

Page 6: ...the frozen condensed water will block up the water outlet please pull out the rubber stopper of the reserve water outlet If that still fails to satisfy for the water draining please knock open the ot...

Page 7: ...connected to the indoor unit is at least 0 5m 4 4 Connecting method main pipe The branch pipes of indoor unit The pipe after the first branch do not drect connect with the indoor unit The pipe after...

Page 8: ...g nut 15 9 Flaring nut 6 4 Flaring nut Wall mounted 56 15 9 Flaring nut 9 5 Flaring nut 6 4 Flaring nut 9 5 Flaring nut 9 5 Flaring nut One sided air outlet 18 45 12 7 Flaring nut 6 4 Flaring nut One...

Page 9: ...e gas side main pipe size Inner branch pipes are a f the size selection please refers to Table4 6 Note The max length of the branch pipe should not longer than 15m Indoor unit branch pipe The main pip...

Page 10: ...t to be Added Using vacuum pump to do the vacuum never using refrigerant to expel the air Vacuuming should be done from both liquid side and gas side simultaneously Calculate the added refrigerant acc...

Page 11: ...rol system connection of the outdoor unit P Q E L N P Q E L N P Q E L N P Q E L N L2 L3 N L1 K2 E O K1 A E Y E P X Q E Power supply for the outdoor unit monitor Outdoor unit Reserved Optional L N K1 K...

Page 12: ...he signal cable insert electric wires in their respective electric wire pipes and reserve a proper inter wire distance distance between power cables lower than 10 A 300 mm lower than 50 A 500 mm Use a...

Page 13: ...NOTE Single phase indoor unit Wire controller The reserved wire control function is indicated in broken line table users can purchase the wire controller when necessary in broken line table users can...

Page 14: ...tilator A Ventilation peristome Leak hunting siren should be installed in places easily keep refrigerant Indoor unit Outdoor unit Indoor unit Room full of leak refrigerant All refrigerant has run up F...

Page 15: ...ween main board and compressor drive board Inverter module protection Qty of indoor units mismatching High pressure sensor error M HOME for the indoor and outdoor units does not match Phase sequence e...

Page 16: ...equipment Failure to observe a warning may result in death The appliance shall be installed in accordance with national wiring regulations Do not use the air conditioner for other purposes In order to...

Page 17: ...t supervision When capacity of indoor unit greater than the sum of 100 capacity of indoor unit will be attenuated When capacity of indoor unit greater than or equal to the sum of 120 in order to ensur...

Page 18: ...starts immediately after operation The indoor unit of the intelligent inverter centralized air conditioner can be controlled solely but the indoor unit in the same system can not run cooling and heati...

Page 19: ...ble Irrecoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable Recoverable P8 F1 E1 High pressure protection M HOME for the indoor and outdoor units does not match Display F...

Page 20: ...d when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after h...

Page 21: ...indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is to...

Page 22: ...r goes off after a lapse of certain time Check whether the timer operation is started when the TIMER ON is indicated on the display Up to the set time the air conditioner will automatically start and...

Page 23: ...3 6 4 2 6 732C 3 2C 87 5 3 6 37 3 37 62 and hydrogen sulphide G F7 2 88 8 7 62 26 5 26 63 2 5 E6 3 where the air conditioning is on for 24 hours a day As the use of the unit for many years will eventu...

Page 24: ...oad at given outdoor temperatures Tj Prated c Pdc Pdc Pdc Pdc Cdc 0 25 33 5 kW Seasonal space cooling energy efficiency s c 199 8 Symbol Value Unit Off mode Thermosat off mode Crankcase heater mode St...

Page 25: ...d heating capacity Degradation co efficient for heat pumps Declared heating capacity for part load at indoor teperature 20 and outdoor temperatures Tj Declared coefficient of performance or gas utilis...

Page 26: ...y factor for part load at given outdoor temperatures Tj Prated c Pdc Pdc Pdc Pdc Cdc 0 25 28 0 kW Seasonal space cooling energy efficiency s c 201 0 Symbol Value Unit Off mode Thermosat off mode Crank...

Page 27: ...ed heating capacity Degradation co efficient for heat pumps Declared heating capacity for part load at indoor teperature 20 and outdoor temperatures Tj Declared coefficient of performance or gas utili...

Page 28: ...www mundoclima com C N POLES 249 P1 08013 BARCELONA SPAIN 34 93 446 27 80...