22
Install the indoor unit
1.When routing the piping and wiring from the left or right
side of the indoor unit, cut off the tailings from the chassis
in necessary (shown in Fig.4)
Cut off the tailingsl when routing the wiring only.
Cut off the tailingsl and tailings 2 when routing both the
wiring and piping.
2.Wrap the piping and wiring and pull them through the cut-
off -tailings hole (shown in Fig. 5).
3.Hang the 2 mounting slots of the indoor unit on the upper
tabs of the real panel and check if it is firm enough.
4.The height of the installed location should be 2.3m or more
from the floor.
NOTE:
All the electrical work must be done by qualified personnel according to the local rules and this manual.
The rated voltage and the exclusive circuit must be used.
Leakage circuit - breaker must be installed.
Please use specified fuse.
The diameter of power cord should be large enough.Use the cxclusive wire to replace the damaged wire.
Wiring work should conform to national standard.
Switches shall be connected to the supply teminals and shall have a contact separation of at least 3mm in each
pole.
N(1)
2
3
Wiring cover plate
Power connection cord
Tailings3
Tailings2
Tailings1
Power connection cord
Drain hose
control cord
Connection pipes
Wrapping tape
(Fig.4)
(Fig.3)
(Fig.5)