2.   USER

2.1 Machine description

The  fan-coil  unit  for  the  threatment  of  air  in  indoor  
environments,available  in  versions  with  casing,versions  for  
building-in. 

2.1.1  Standard conditions of use 

The fan-coil unit is intended for the treatment of air(summer and  
winter climatisation)inside buildings used for domestic or similar  
purposes.The unit is not designed for installation in roomsused  
for laundry purposes. 

CAUTION 

DANGER! 

The  machines  are  designed  for  indoor  installation  for  use  in  
domestic or similar environments. 

DANGER! 

Do  not  introduce  objects  through  the  air  intate  or  delivery  
grilles. 

IMPORTANT! 

The unit will function correctly only if the instructions for use  
are  scrupulously  followed,if  the  specified  clearances  are  
complied  with  during  installation  and  if  the  operating  
restrictions indicated in this manual are strictly adhered to. 

IMPORTANT! 

If  clearance  distances  are  not  maintained  at  installation,it  
could  cause  maintenance  difficulties  and  reduction  in  
performance. 

2.1.2  Construction features

1. Connections for standard coil; 
2. Fixing slots; 
3. Defrosting tray; 
4. Condensate discharge; 
5. Air filter; 
6. Blower; 
7. Coils

Fig.2-1 

DISPOSAL

˖

Do not dispose this product as unsor- 

ted municipal waste. Collection of such waste sepa- 
rately for

special treatment is necessary. 

Ground the air conditioner.

 

Do  not  connect  the  ground  wire  to  gas  or  water  pipes, 
lightning  rod  or  a  telephone  ground  wire.Incomplete 
grounding may result in electric shocks. 
 

Be sure to install an earth leakage breaker.

 

Failure  to  install  an  earth  leakage  breaker  may  result  in 
electric shocks.

 

 

Connect the outdoor unit wires , then connect the indoor 
unit wires.

  

You  are  not  allow  to  connect  the  air  conditioner  with  the 
power  source  until  wiring  and  piping  the  air  conditioner  is 
done. 

 
While  following  the  instructions  in  this  installation 
manual,  install  drain  piping  in  order  to  ensure  proper 
drainage  and  insulate  piping  in  order  to  prevent 
condensation.

 

Improper  drain  piping  may  result  in  water  leakage  and 
property damage. 
 

Install the indoor and outdoor units, power supply wiring 
and  connecting  wires  at  least  1  meter  away  from 
televisions  or  radios  in  order  to  prevent  image 
interference or noise. 

Depending on the radio waves, a distance of 1 meter may not 
be sufficient enough to eliminate the noise. 

 
This  appliance  is  not  intended  for  use  by  persons 
(including  children)  with  reduced  physical,sensory  or 
mental capabilities, or lack of experience and knowledge, 
unless  they  have  been  given  supervision  or  instruction 
concerning use of the appliance by a person responsible 
for their safety. 

 

 
 
 
 
 
Don't install the air conditioner in the following locations: 

There is petrolatum existing. 
 
There is salty air surrounding (near the coast). 
 
There is caustic gas (the sulfide, for example) existing  
in the air (near a hot spring). 
 
The Volt vibrates violently (in the factories). 
 
In buses or cabinets. 
 
In kitchen where it is full of oil gas. 
 
There is strong electromagnetic wave existing. 
 
There are inflammable materials or gas. 
 
There is acid or alkaline liquid evaporating. 
 
Other special conditions. 

CAUTION 

Installation manual

Universal FCU DC

4

Summary of Contents for MUC-W7/CE

Page 1: ...English www mundoclima com www mundoclima com Universal FCU DC Installation manual MUC W7 CL04580 to CL04594 MUC W7 CE MUC W7 SE...

Page 2: ...INGLE PHASE one phase L and one neutral N with his grounded power GND switch Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer In line with th...

Page 3: ...lace of purchase for more information Excessive refrigerant in a closed ambient can lead to oxygen deficiency Use the attached accessories parts and specified parts for installation otherwise it will...

Page 4: ...cks Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indoor unit wires You are not...

Page 5: ...ction as a ceiling mounted air handling terminal supplied through ducting or panelling any other use is expressly prohibited Installation of the machine in an explosive environment is also forbidden C...

Page 6: ...sable to run the unit at maximum speed for several hours To ensure correct air intake the air filter must be cleaned at least once a month or more frequently if the unit is being used in very dusty en...

Page 7: ...lectrical components Also make sure that there are no obstacles or people along the route to avoid the danger of collisions or crushing and to prevent the lifting or handling device from turning over...

Page 8: ...at the time of installation For installation follow the instructions set out below Remove the external casing in versions CE and SE unscrewing the screws which secure it to the structure as following...

Page 9: ...10 mm thick or install the auxiliary drain Pour water into the condensation collector tray and check that the liquid drains properly following it right through to the exit of the draintube If it does...

Page 10: ...ecting cables and strip only the length of cable needed to go into the connector block In the event that the unit is mounted on a metal surface earth connections must be made in compliance with local...

Page 11: ...no obstructions in the condensation drain tube which could prevent the normal flow of water 1 2 4 3 remove the casing of the machine start the system and run for a few minutes stop the system slacken...

Page 12: ...procedures The unit should only be dismantled by a firm authorized for the disposal of scrap machinery The unit as a whole is composed of materials considered as secondary raw materials and the follo...

Page 13: ...00 1200 900 700 500 D mm 1226 1226 926 726 526 Installation manual Universal FCU DC Model MUC 07 W7 CE MUC 11 W7 CE MUC 16 W7 CE MUC 19 W7 CE MUC 24 W7 CE 13 220 Rear view 105 46 D C 150 150 220 592 1...

Page 14: ...E A C 212 87 Water connection Rear view 46 105 203 291 185 258 Fig 4 6 Fig 4 7 Fig 4 8 A mm B mm C mm D mm Model MUC 07 W7 SE MUC 11 W7 SE MUC 16 W7 SE MUC 19 W7 SE MUC 24 W7 SE 550 526 500 532 750 72...

Page 15: ...0 471 V F Hz 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 W 16 33 29 39 116 MPa 1 6 1 6 1 6 1 6 1 6 C 65 65 65 65 65 inch 3 4 3 4 3 4 3 4 3 4 mm 16 16 16 16 16 Version SE W x H x...

Page 16: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...