background image

Remove the casing (on units CE and  SE); 

Isolate the flow and return water pipes; 

Disconnect the coil from the water system; 

Remove  the  screws  on  both  sides  which  hold  the  
coil to the structure of the unit; 

Take out the heat-exchanger coil. 

Replacement of the heat-exchanger coil 

Procedure for removal of the heat-exchanger: 

DISMANTLING  THE  UNIT  AND  DISPOSAL  OF  
HARMFUL SUBSTANCES 

Procedure  for  refitting  the  heat-exchanger  is  a  
reversal of the above. 

PRESERVE THE ENVIRONMENT! 

We  care  about  protecting  the  environment.  When  the  unit  is  

dismantled it is important to adhere scrupulously to the following  

procedures. 

The unit should only be dismantled by a firm authorized  
for the disposal of scrap machinery. 

The unit as a whole is composed of materials considered  
as secondary raw materials and the following conditions  
must be observed: 

If the system has antifreeze as an additive,it must not be 
just dumped,because it causes pollution.It should be 
collected and suitably disposed of.

The electronic components(electrolytic condensers) 
should be considered special waste,and as such they 
should be delivered to a firm authorised to collect them.

The expanded polyurethane rubber insulation on the 
pipes and the expanded polyethylene mesh,the xpanded 
polyurethane and sound-absorbent spong lining the 
bodywork must be removed and processed as urban 
refuse.

1

2

3

Fig.3-12 

  

  

Installation manual

Universal FCU DC

12

Summary of Contents for MUC-W7/CE

Page 1: ...English www mundoclima com www mundoclima com Universal FCU DC Installation manual MUC W7 CL04580 to CL04594 MUC W7 CE MUC W7 SE...

Page 2: ...INGLE PHASE one phase L and one neutral N with his grounded power GND switch Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer In line with th...

Page 3: ...lace of purchase for more information Excessive refrigerant in a closed ambient can lead to oxygen deficiency Use the attached accessories parts and specified parts for installation otherwise it will...

Page 4: ...cks Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indoor unit wires You are not...

Page 5: ...ction as a ceiling mounted air handling terminal supplied through ducting or panelling any other use is expressly prohibited Installation of the machine in an explosive environment is also forbidden C...

Page 6: ...sable to run the unit at maximum speed for several hours To ensure correct air intake the air filter must be cleaned at least once a month or more frequently if the unit is being used in very dusty en...

Page 7: ...lectrical components Also make sure that there are no obstacles or people along the route to avoid the danger of collisions or crushing and to prevent the lifting or handling device from turning over...

Page 8: ...at the time of installation For installation follow the instructions set out below Remove the external casing in versions CE and SE unscrewing the screws which secure it to the structure as following...

Page 9: ...10 mm thick or install the auxiliary drain Pour water into the condensation collector tray and check that the liquid drains properly following it right through to the exit of the draintube If it does...

Page 10: ...ecting cables and strip only the length of cable needed to go into the connector block In the event that the unit is mounted on a metal surface earth connections must be made in compliance with local...

Page 11: ...no obstructions in the condensation drain tube which could prevent the normal flow of water 1 2 4 3 remove the casing of the machine start the system and run for a few minutes stop the system slacken...

Page 12: ...procedures The unit should only be dismantled by a firm authorized for the disposal of scrap machinery The unit as a whole is composed of materials considered as secondary raw materials and the follo...

Page 13: ...00 1200 900 700 500 D mm 1226 1226 926 726 526 Installation manual Universal FCU DC Model MUC 07 W7 CE MUC 11 W7 CE MUC 16 W7 CE MUC 19 W7 CE MUC 24 W7 CE 13 220 Rear view 105 46 D C 150 150 220 592 1...

Page 14: ...E A C 212 87 Water connection Rear view 46 105 203 291 185 258 Fig 4 6 Fig 4 7 Fig 4 8 A mm B mm C mm D mm Model MUC 07 W7 SE MUC 11 W7 SE MUC 16 W7 SE MUC 19 W7 SE MUC 24 W7 SE 550 526 500 532 750 72...

Page 15: ...0 471 V F Hz 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 W 16 33 29 39 116 MPa 1 6 1 6 1 6 1 6 1 6 C 65 65 65 65 65 inch 3 4 3 4 3 4 3 4 3 4 mm 16 16 16 16 16 Version SE W x H x...

Page 16: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...

Reviews: