MultiVOIP FX Cabling Guide
4
Multi-Tech Systems, Inc.
•
Ensure that the MultiVOIP is properly connected to earth ground via a
grounded power cord. If a power strip is used, ensure that the power strip
provides adequate grounding of the attached apparatus.
•
Ensure that the mains supply circuit is capable of handling the load of the
MultiVOIP. Refer to the power label on the equipment for load requirements.
•
Maximum ambient temperature for the MultiVOIP is 60 degrees Celsius
(140
°
F) at 20-90%s non-condensing relative humidity.
•
This equipment should only be installed by properly qualified service
personnel.
•
Only connect like circuits. In other words, connect SELV (Secondary Extra
Low Voltage) circuits to SELV circuits and TN (Telecommunications
Network) circuits to TN circuits.
•
To reduce the risk of shock, all access doors should be closed during
normal operation of the equipment.
MultiVOIP Package Contents
•
One MultiVOIP FX
•
One power cord
•
One Console Cable (RJ45 to DB25 connectors)
•
Two rack mount brackets and four mounting screws for -4 and -8 models
•
One printed Cabling Guide.
•
One MultiVOIP CD containing software and user documentation.
Cabling the MVPFX2-2
Cabling involves connecting the MultiVOIP to your LAN and telephone equipment.
Power Connection
Voice/Fax Channel 1 - 2
Connections
FXS FXO
FXS
PSTN
FXO
FXS
FXS
FXO
FXO
VOICE/FAX 1
WAN
CONSOLE
10/100
RS-2 32
VOICE/FAX 2
POWER
RJ-11
Connector s
RJ- 45
Cable
Grounding
Cable
Ethe rnet
Default IP
192.168.2.1
PC IP
192.168.2.X