81
Chapter 6 - S-Registers
S15
Callback Time Delay
Unit:
Seconds
Range:
10-255
Default:
20
Description:
S15 defines the time delay between Callback attempts after initial passwords have
been exchanged between modems. Refer to
Chapter 7
for Callback Security
information.
S16
Callback Attempts
Unit:
1 Attempt
Range:
1-255
Default:
4
Description:
S16 defines the number of attempts allowed after initial passwords have been
exchanged between modems.
S17
Changing Break Time
Unit:
10 mSec.
Range:
0-2.5 sec
Default:
250
Description:
S17 defines the break time (space) sent to the local PC. The default is set for a 25 to
250 mSec break. The break time can be changed in 10 mSec increments by
increasing or decreasing the value of S17.
S24
PBX/CBX Disconnect Drop Time for DSR/CTS/CD
Unit:
50 mSec.
Range:
0-255
Default:
20
Description:
Some PBX and CBX phone systems require the modem’s DSR, CTS, and/or CD
signal(s) to behave in a certain manner when calls are disconnected. The modem’s
&R, &S, and &C commands cause the modem to drop these signal(s) for a specified
time period upon disconnect, and then bring the signal(s) up again. S24 defines the
length of time that the signals drop. The default setting of 20 results in a one second
drop time, which is what most PBX/CBX systems with this requirement need.
S25
DTR Dropout Time
Unit:
100 mSec.
Range:
0, 1 through 255
Default:
0
Description:
S25 defines the amount of time that DTR must be dropped before the modem
disconnects. Typically, a disconnect occurs when DTR is dropped for 50
milliseconds or more. This dropout time can be increased, up to a maximum of 25.5
seconds. The S25 unit value for zero is the default value of 50 mSec. For values
from 1 through 255, the unit value is 100 mSec.
Summary of Contents for MultiModem II BA-Series
Page 1: ...BA Series Intelligent Data Fax Modem User Guide...
Page 6: ...vi...
Page 7: ...Chapter 1 Introduction and Description...
Page 18: ...18 MultiModemBA User Guide...
Page 19: ...Chapter 2 Installation and Connection...
Page 26: ...26 MultiModemBA User Guide...
Page 27: ...Chapter 3 Software Configuration and Modem Basics...
Page 34: ...34 MultiModemBA User Guide...
Page 35: ...Chapter 4 Manual Dial and Automatic Answer...
Page 40: ...40 MultiModemBA User Guide...
Page 41: ...Chapter 5 Command Mode...
Page 76: ...76 MultiModemBA User Guide...
Page 77: ...Chapter 6 S Registers...
Page 86: ...86 MultiModemBA User Guide...
Page 87: ...Chapter 7 Callback Security and Remote Configuration...
Page 96: ...96 MultiModemBA User Guide...
Page 97: ...Chapter 8 Modem Testing...
Page 106: ...106 MultiModemBA User Guide...
Page 107: ...Chapter 9 DIP Switch Settings...
Page 117: ...Chapter 10 Warranty Service and Tech Support...
Page 123: ...Appendixes...