Multitech MultiModem GPRS with Ethernet Interface User Manual Download Page 3

   12 
  IN ALARM: 
   59min 12sec 
  Reply with 0 for menu. 
  Omniguard 4 
  # G400000 

 
In order to support more wireless phone numbers along with email addresses, the 

Omniguard can store up to four Notify Lists. These lists allow different phone numbers 
and/or email addresses for alarm and normal operation notification and reports. They also 
allow the report time to be changed. Notify Lists can only be created and programmed 
into the Omniguard using the Omniguard Communications PC software available at 

www.engsolinc.com

.  See the help that comes with the software for more information on 

setting up Notify Lists. 
 
To configure and test the wireless modem – 

1.

 

Connect the modem to the Omniguard as described above.  

2.

 

Highlight WIRELESS MODEM using up and down keys and press SELECT to 
view or change the settings.  

3.

 

If desired, press up and down keys to change Cell # 1, the first of two wireless 
phone numbers that can be programmed on the Omniguard. Once the first digit of 
the number has been changed, use right and left keys to move to the other digits. 
To delete the phone number, set the first digit to a blank. 

4.

 

Press right and left keys to move to Cell # 2. Again use up and down keys to 
change the first digit of the phone number. Once the first digit of the number has 
been changed, use right and left keys to move to the other digits. 

5.

 

Press right and left keys to move to Notify. If you have programmed one or more 
Notify Lists into the Omniguard using the Omniguard Communications PC 
software, you can select on of them using “up/down”. 

6.

 

Press right and left keys to move to Test Modem. When “Test” is selected, 
pressing the SELECT key will cause a message to be sent to the Cell # 1 and Cell 
# 2 phone numbers as well as any numbers or email addresses in the chosen 
Notify List. 

7.

 

Press SAVE to save the settings and return to the Main Menu.  

 
Pressing the EXIT key will return you to the Main Menu without saving the updated 
settings. 

 

Requesting Information 

It is also possible to request information from an Omniguard connected to a wireless 

modem. A text message or email is sent to the Omniguard which will reply with a report 
based on the content of the message. The reports include a daily summary, overall job 
summary, current status and settings. To get a complete list of reports the Omniguard can 
provide send a text message or email with a “0” (zero) in the body of the message.  

Text messages must sent to the Omniguard must be in the “short message” format and 

are sent to the phone number of the wireless modem. Email message must be in plain text 
format and should be sent to the email address provided by the wireless service provider. 