background image

MULTICONNECT MICROCELL USER GUIDE

2

MultiConnect

®

microCell MTCM2-L6G1 User Guide

MultiConnect microCell User Guide

Model: MTCM2-L6G1

Part Number: S000752 1.1

Copyright

This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of
Multi-Tech Systems, Inc. All rights reserved.

Copyright © 2020 by Multi-Tech Systems, Inc.

Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information,
material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and non-
infringement.

Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.

Trademarks

MultiTech

®

, the MultiTech logo, and MultiConnect are registered trademarks of Multi-Tech Systems, Inc. All other brand and product names are trademarks

or registered trademarks of their respective companies.

Legal Notices

The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with
applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or
death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life
preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or
missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted
Applications is at the user’s sole risk and liability.

The MultiTech products and the final application of the MultiTech products should be thoroughly tested to ensure the functionality of the MultiTech
products as used in the final application. The designer, manufacturer and reseller has the sole responsibility of ensuring that any end user product into
which the MultiTech product is integrated operates as intended and meets its requirements or the requirements of its direct or indirect customers.
MultiTech has no responsibility whatsoever for the integration, configuration, testing, validation, verification, installation, upgrade, support or maintenance
of such end user product, or for any liabilities, damages, costs or expenses associated therewith, except to the extent agreed upon in a signed written
document. To the extent MultiTech provides any comments or suggested changes related to the application of its products, such comments or suggested
changes is performed only as a courtesy and without any representation or warranty whatsoever.

Contacting MultiTech

Knowledge Base

The Knowledge Base provides immediate access to support information and resolutions for all MultiTech products. Visit

http://www.multitech.com/kb.go

.

Support Portal

To create an account and submit a support case directly to our technical support team, visit:

https://support.multitech.com

.

Support

Business Hours: M-F, 8am to 5pm CT

Country

By Email

By Phone

Europe, Middle East, Africa:

[email protected]

+(44) 118 959 7774

U.S., Canada, all others:

[email protected]

(800) 972-2439 or (763) 717-5863

Warranty

To read the warranty statement for your product, visit

https://www.multitech.com/legal/warranty

. For other warranty options, visit

www.multitech.com/es.go

.

World Headquarters

Multi-Tech Systems, Inc.

2205 Woodale Drive, Mounds View, MN 55112

Phone: (800) 328-9717 or (763) 785-3500

Fax (763) 785-9874

Summary of Contents for MultiConnect microCell MTCM2-L6G1

Page 1: ...MultiConnect microCell MTCM2 L6G1 User Guide...

Page 2: ...biological or chemical weapons or other military applications Restricted Applications Use of the products in such Restricted Applications is at the user s sole risk and liability The MultiTech product...

Page 3: ...rs and Other Medical Devices 12 Potential interference 12 Precautions for pacemaker wearers 12 Chapter 3 Installing Drivers 13 Installing on Linux 13 Installing Windows Drivers 13 Uninstall driver bef...

Page 4: ...ive 19 Instructions for Disposal of WEEE by Users in the European Union 19 REACH Statement 19 Registration of Substances 19 Restriction of the Use of Hazardous Substances RoHS 20 Information on HS TS...

Page 5: ...erview The following documents are available at https www multitech com brands multiconnect microcell Select your model to find the documents specific for that device Document Description Part Number...

Page 6: ...PRODUCT OVERVIEW 6 MultiConnect microCell MTCM2 L6G1 User Guide Dimensions...

Page 7: ...to Dimensions for dimensions Connectors Antenna Connector 2 SMA connectors SIM 1 8V and 3V SIM holder for micro SIM 3FF card USB USB 2 0 with High Speed up to 480 Mbps Environment Operating Temperatur...

Page 8: ...5 Volts USB LTE Band 43 3700Mhz N A N A 477 mA 784 mA 0 135 mC 22 1 uS LTE Band 42 3500Mhz N A N A 482 mA 792 mA 0 135 mC 22 1 uS LTE Band 48 3625Mhz N A 173 mA 473 mA 768 mA 0 135 mC 22 1 uS Note 1 M...

Page 9: ...Power On Device has power Off Device does not have power Link Status LS On Radio is not registered Flash Slow Registered Off Radio is turned off in PSM mode receiving a firmware update or SIM is not i...

Page 10: ...DUCT OVERVIEW 10 MultiConnect microCell MTCM2 L6G1 User Guide Additional Signal LED Information Signal LED is based on CESQ RSRP and RSRQ RSRP RSRQ On 90 10 Fast 105 11 to 15 Slow 120 16 to 19 Off 120...

Page 11: ...in use S curit relative aux appareils radiofr quence RF cause du risque d interf rences de radiofr quence RF il est important de respecter toutes les r glementations sp ciales relatives aux quipements...

Page 12: ...rmful interference occurs the FDA will assess the interference and work to resolve the problem Precautions for pacemaker wearers If EMI occurs it could affect a pacemaker in one of three ways Stop the...

Page 13: ...ver the private LTE network via the Ethernet cellular IP address interface Installing Windows Drivers CAUTION If you connected the device before installing the drivers Windows may install drivers auto...

Page 14: ...Windows 10 To uninstall drivers from Windows 10 1 Open the Start Menu and click Settings 2 Click System 3 Click Apps Features 4 In the Apps Features pane scroll down to Sequans 4G solution where is t...

Page 15: ...evice Important Install drivers on your computer before connecting the device 1 Connect antennas to the antenna connectors 2 Connect the USB connector to your computer or other USB high power device s...

Page 16: ...m setting for auto network connection AT SQNAUTOCONNECT AT AUTOATT Troubleshooting the Connection If the device does not connect to your network Check the SIM card Verify it is activated and allowed t...

Page 17: ...gn process therefore it is essential to consider it early so the performance is not compromised Devices were approved with the following antenna s and for alternate antennas meeting the given specific...

Page 18: ...ld void the user s authority to operate the equipment FCC Interference Notice This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may...

Page 19: ...duct or on its packaging which indicates that this product must not be disposed of with other waste Instead it is the user s responsibility to dispose of their waste equipment by handing it over to a...

Page 20: ...t contain the following banned chemicals1 Lead Pb 1000 PPM Mercury Hg 100 PPM Cadmium Cd 100 PPM Hexavalent Chromium Cr 6 1000 PPM Polybrominated Biphenyl PBB 1000 PPM Polybrominated Diphenyl Ethers P...

Page 21: ...ated Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O...

Page 22: ...in Chinese MII EIP 39 RoHS Multi Tech Systems Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O ICs O O O O O O O O O O O O X O O O O O O O O O O O O O O O O...

Reviews: