Multitech MTSMC-C2-GP-N16 Device Manual Download Page 12

 

CHAPTER 3 –SPECIFICATIONS 

 

 

SocketModem CDMA MTSMC-C2 Device Guide 

12 

 

MTSMC-C2  

Radio Protocol 

Sleep Mode 
Current 
(Amps) 

Cellular Call Box 
Connection No 
Data (Amps) 

Average Measured 
Current (Amps) at 
Maximum Power 

Peak TX 
Amplitude 
Current (Amps) 

Total Inrush Charge 
measured in 
Millicoulombs 

3.3 Volts 

US Cellular 

0.034 

0.055 

0.687 

0.744 

1.08 

PCS 

0.034 

0.055 

0.865 

0.92 

1.08 

5 Volts 

US Cellular 

0.032 

0.044 

0.445 

0.5 

1.52 

PCS 

0.032 

0.045 

0.552 

0.604 

1.52 

MTSMC-C2-IP 

Radio Protocol 

Cellular Call Box 
Connection No Data 
(Amps) 

Average Measured 
Current (Amps) at 
Maximum Power 

Peak TX Amplitude 
Current (Amps) 

Total Inrush 
Charge measured 
in Millicoulombs 

3.3 Volts 

US Cellular 

0.142 

0.736 

0.795 

3.37 

PCS 

0.141 

1.244 

1.319 

3.37 

5 Volts 

US Cellular 

0.099 

0.457 

0.512 

1.73 

PCS 

0.1 

0.689 

0.747 

1.73 

MTSMC-C2-GP 

Radio Protocol 

Cellular Call Box 
Connection No Data 
(Amps) 

Average Measured 
Current (Amps) at 
Maximum Power 

Peak TX Amplitude 
Current (Amps) 

Total Inrush 
Charge measured 
in Millicoulombs 

3.3 Volts 

US Cellular 

0.257 

0.903 

0.976 

3.37 

PCS 

0.255 

1.358 

1.44 

3.37 

5 Volts 

US Cellular 

0.175 

0.564 

0.632 

1.73 

PCS 

0.173 

0.767 

0.832 

1.73 

 

Notes: 

  

 

Maximum:

 The continuous current during maximum data rate with the radio transmitter at maximum power. 

 

Peak TX:

 The peak current during a CDMA transmission burst period. 

 

In-Rush Charge:

 The total input charge during power up. 

 

Summary of Contents for MTSMC-C2-GP-N16

Page 1: ...SocketModem Cell CDMA SocketModem iCell CDMA MTSMC C2 Device Guide...

Page 2: ...iversal IP and the Multi Tech logo are registered trademarks of Multi Tech Systems Inc Microsoft and Windows are registered trademarks of Microsoft Corporation in the United States and other countries...

Page 3: ...ing 10 Electrical Characteristics Other Pins 10 Pinout Specifications 10 Pin 58 11 Pin Availability by Build 11 Power Measurements 11 MTSMC C2 12 MTSMC C2 IP 12 MTSMC C2 GP 12 Chapter 4 FCC and Indust...

Page 4: ...e 4 LED 1 Heartbeat IP and GP Builds Only 18 LED 2 Link Status All Builds 18 LED 3 Signal Strength IP and GP Builds Only 18 LED 4 GPS Status GP Builds 18 RF Performances 19 Receiver Features 19 Transm...

Page 5: ...Cell 800 1900 MHz CDMA 1xRTT Sprint with Universal IP USA Builds using Verizon Wireless Services MTSMC C2 N3 SocketModem Cell 800 1900 MHz CDMA 1xRTT Verizon Data Only USA MTSMC C2 GP N3 SocketModem i...

Page 6: ...r information Universal Socket Developer Guide Provides an overview safety and regulatory information design considerations schematics and general device information S000342 USB Driver Installation Gu...

Page 7: ...CHAPTER 2 MECHANICAL DRAWINGS 7 SocketModem CDMA MTSMC C2 Device Guide Chapter 2 Mechanical Drawings MTSMC C2 Builds...

Page 8: ...torage Temperature 40 C to 85 C Humidity 20 to 90 non condensing Power Requirements Operating Voltage 3 3 5VDC 10 IP M2M SMS Supported IP Protocols DNS resolve FTP client ping POP3 client PPP dialout...

Page 9: ...reset Model Time Constant X Time Minimum Reset Pulse1 Maximum Reset Pulse MTSMC C2 250 ms 10 seconds 200 s Less than 1 second 1 The SocketModem may respond to a shorter reset pulse Powering Down Your...

Page 10: ...evel Voltage1 I O Description J24 RESET 3 3 5 0 I Device reset active low J26 GND GND GND Ground J33 RTS 3 3 5 0 I Request to send active low J34 RXD 3 3 5 0 O Received data active low J35 TXD 3 3 5 0...

Page 11: ...transfer When a transfer is in progress the LED goes on within 1 second after data packets were exchanged Flash duration is approximately 0 5 s ON Connected to remote party or parameter exchange whil...

Page 12: ...Amplitude Current Amps Total Inrush Charge measured in Millicoulombs 3 3 Volts US Cellular 0 142 0 736 0 795 3 37 PCS 0 141 1 244 1 319 3 37 5 Volts US Cellular 0 099 0 457 0 512 1 73 PCS 0 1 0 689 0...

Page 13: ...ments of 2 1091 is 5 12dBi for part 22H and 6 12dBi for part 24E The antenna s used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must...

Page 14: ...roved device circuit board or antenna system All applications interacting with Sprint approved Multi Tech devices must be written in a manner where they do not interfere interrupt the Sprint HFA proce...

Page 15: ...ed DREL Data session release Network Initiated Device Configuration NIDC or Client Initiated Device Configuration CIDC 906 DC Session started 911 DC Error credential error 912 DC Error unreachable ser...

Page 16: ...available after the unsolicited indication 900 appears which means DM client is ready AT OMADMSVADDR URL Set OMA DM server address default https oma ssprov sprint com oma AT OMADMSVADDR Read OMA DM se...

Page 17: ...ANCEL Cancel Preferred Roaming List PRL Session AT PRL Query Preferred Roaming List PRL ID AT FUMOCANCEL Cancel Firmware Update Management Object FUMO session Sprint Successful Indications Typical Suc...

Page 18: ...ed and passing data Slow blink 0 2Hz Registered to tower and idle Faster blink 3Hz Powered not registered Searching for registration Note For non IP builds to ensure that the Link Status LED works pro...

Page 19: ...3GPP Release 5 6 All values indicated are conducted Receiver Features Category Description CDMA 1xRTT US Cellular 800 Verizon sensitivity 108 dBm CDMA 1xRTT US PCS 1900 Sprint sensitivity 107 dBm Tran...

Reviews: