51
Chapter 4 - Commands
S25
DTR Dropout Time
Unit:
100 mSec.
Range:
0, 1 through 255
Default:
0
Description:
Defines DTR dropout time. 0 default equals 50ms.
S26
Failed Password Attempts
Unit:
1 failed attempt
Range:
0-255
Default:
0
Description:
Counts the number of times there has been a failed
password attempt.
S29
Local Inactivity Timer
Unit:
minutes
Range:
1-255
Default:
20
Description:
Defines the amount of idle time that can elapse between
AT commands after the SETUP password has been
entered.
S30
Inactivity Timer
Unit:
1 minute
Range:
0-255
Default:
0
Description:
Inactivity timer used to disconnect the modem.
S32
Time Elapse for Escape Sequence
Unit:
1 second
Range:
0-255
Default:
20
Description:
Sets the duration in which modem waits for a <CR> to be
entered during escape sequence execution.
S34
Buffer Length of Command Mode...After On-line Escape Sequence
Unit:
ASCII Character
Range:
0-60
Default:
10
Description:
Sets buffer length of command mode after on-line escape
sequence.