Chapter 7 - Troubleshooting
7.5 Composite Link Settings - Internal DSU
Table 7-5. Composite Link Settings - Internal DSU
Step
Procedure
1
Toggle DIP switch position 3 to the down (closed) position to enable the command port.
2
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker.
Note:
Any cables connected to the computer should be shielded to reduce interference.
3
Apply power to the DataTalker.
4
Apply power to the terminal or PC. Run the PC’s communications software in terminal mode
and press ENTER twice to establish communications with the DataTalker. The Main Menu
appears:
Main Menu
1 - Configurations
2 - Statistics
3 - Reset Options
4 - Diagnostics
5 - Exit Command Mode
6 - QUICK SETUP
Selection : _
5
Enter 1 and press ENTER. The Configurations menu is displayed:
Configurations
1 - Data Port Configuration
2 - Voice/Fax Channel(s) Configuration
3 - Composite Link Configuration
4 - Factory Default Configuration Options
5 - Configure Remote Unit
S - Store All Configurations
M - Main Menu
P - Previous Menu
Selection : _
6
Enter 3 and press ENTER to display the Composite Link Settings - Internal DSU menu.
7
Verify the internal DSU settings. To change settings, enter the appropriate option numbers.
The default settings are correct for a 56K bps DDS line.
C o m p o s i t e L i n k S e t t i n g s - I n t e r n a l D S U
1 - S p e e d : 5 6 k
2 - C l o c k i n g : D D S
S - S t o r e A l l C o n f i g u r a t i o n s
M - M a i n M e n u
P - P r e v i o u s M e n u
S e l e c t i o n : _
8
When all options for the DSU are set, enter S and press ENTER to store all configurations.
Then enter M and press ENTER to return to the Main Menu.
9
Disconnect the terminal or PC from the command port and place DIP switch position 3 in the
up (OPEN) position to change the command/data port to a data channel.
Summary of Contents for DataTalker DT101
Page 6: ......
Page 7: ...Chapter 1 Introduction and Description...
Page 19: ...Chapter 2 Configuration...
Page 35: ...Chapter 3 Front and Rear Panel Descriptions...
Page 43: ...Chapter 4 Unpacking and Configuration...
Page 54: ...54 DataTalker Owner s Manual...
Page 55: ...Chapter 5 Installation...
Page 64: ...64 DataTalker Owner s Manual...
Page 65: ...Chapter 6 Menus...
Page 87: ...Chapter 7 Troubleshooting...
Page 110: ...110 DataTalker Owner s Manual...
Page 111: ...Chapter 8 Warranty Service and Tech Support...
Page 116: ...116 DataTalker Owner s Manual...
Page 117: ...Appendixes...