48
DataTalker Owner’s Manual
4.7 Configuration Procedure
Table 4-1. Configuration Procedure
Step
Procedure
1
Review the configuration considerations for the data port, the voice/fax channel, and the
composite link in the previous sections.
2
Place DIP switch position 3 in the down (closed) position to enable the command port.
MODEM
DSU/TA
DIAL-UP
LEASED
DIGITAL
VOICE/FAX CHANNEL 1
FXO
FXS
EXTERNAL COMPOSITE
DATA/COMMAND
RS232C/V.35
E&M
INTERNAL COMPOSITE
POWER
GND
DIP
Switch
3
Desktop version: Connect the DC power supply shipped with the DataTalker to the power
connector on the back panel and to the AC outlet.
Rack-mounted version: Insert the DataTalker into a RackTalker rack.
4
Connect a terminal or PC running communications software to the DATA/COMMAND
connector on the back panel of the DataTalker. Use an appropriate RS232 cable to connect
the DATA/COMMAND connector to your PC’s serial port. The terminal or PC serial port may
be labeled COM1, COM2, or Serial Port. The DATA/COMMAND connector has a DCE
physical interface.
MODEM
DSU/TA
DIAL-UP
LEASED
DIGITAL
VOICE/FAX CHANNEL 1
FXO
FXS
EXTERNAL COMPOSITE
DATA/COMMAND
RS232C/V.35
E&M
INTERNAL COMPOSITE
POWER
GND
DATA/COMMAND
Connector
RS232 Cable
Note:
Any cables connected to the computer should be shielded to reduce interference.
5
Desktop version: Apply power to the DataTalker by placing the power switch on the back
panel in the on (I) position.
Rack-mounted version: Apply power to the RackTalker rack if it is not already on.
MODEM
DSU/TA
DIAL-UP
LEASED
DIGITAL
VOICE/FAX CHANNEL 1
FXO
FXS
EXTERNAL COMPOSITE
DATA/COMMAND
RS232C/V.35
E&M
INTERNAL COMPOSITE
POWER
GND
Power
Switch
Summary of Contents for DataTalker DT101
Page 6: ......
Page 7: ...Chapter 1 Introduction and Description...
Page 19: ...Chapter 2 Configuration...
Page 35: ...Chapter 3 Front and Rear Panel Descriptions...
Page 43: ...Chapter 4 Unpacking and Configuration...
Page 54: ...54 DataTalker Owner s Manual...
Page 55: ...Chapter 5 Installation...
Page 64: ...64 DataTalker Owner s Manual...
Page 65: ...Chapter 6 Menus...
Page 87: ...Chapter 7 Troubleshooting...
Page 110: ...110 DataTalker Owner s Manual...
Page 111: ...Chapter 8 Warranty Service and Tech Support...
Page 116: ...116 DataTalker Owner s Manual...
Page 117: ...Appendixes...