       All safety related  codifications, symbols and instructions that appear in this operating manual 
or on the equipment must be strictly followed to ensure the safety of the operating personnel as 
well as the instrument. 

      If all the equipment is not handled in a manner specified by the manufacturer, it might impair the 
protection provided by the equipment .

Product improvement and upgrade is a constant procedure. So for more updated operating information and support, 
Please contact our helpline : +91-9978991474/76/82 or Email at [email protected]        Ver: 05-2017

=>

 Read complete instructions prior to installation and operation of the unit. 

WARNING

 : Risk of electric shock.

 3)  Cable used for connection to power source, must have a cross section of 1mm or greater. These wires 
       should have insulations capacity made of at least 1.5kV.      

 2) To reduce electro magnetic interference, use wire with adequate rating and twists of the same of equal size shall 
      be made with shortest connection.            

 4)  When extending the thermocouple lead wires, always use thermocouple compensation wires for wiring for the RTD
       type, use a wiring material with a small lead resistance (5

Ω

 max per line)and no resistance differentials among  

       three wires should be present.        

 1) To prevent the risk of electric shock power supply to the equipment must be kept OFF while doing the wiring 
      arrangement. Do not touch the terminals while power is being supplied.  

 5)  A better anti-noise effect can be expected by using standard power supply cable for the instrument.         

1) This equipment, being built-in-type, normally becomes a part of main control panel and such in case the 
    terminals do not remain accessible to the end user after installation and internal wiring.  

2) Do not allow pieces of metal, wire clippings, or fine metallic fillings from installation to enter the product 
     or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator.      
3) Circuit  breaker or mains switch must be installed between power source and supply terminal to 
    facilitate power ‘ON’ or ‘OFF’ function. However this mains switch or circuit breaker must be 
     installed at convenient place normally accessible to the operator.     
4) Use and store the instrument within the specified ambient temperature and humidity ranges as 
     mentioned in this manual.     

Warning Guidelines

Safety Precautions

Installation Guidelines

Mechanical Installation

Maintenance

1) Prepare the panel cutout with proper dimensions as show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in close proximity to any heating source, 
    caustic vapors, oils steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to wire the terminal block. Tightening the
     screws on the terminal block using the tightening torque of the range of 1.2 N.m.
5) Do not connect anything to unused terminals. 
   

1) The equipment should be cleaned regularly to avoid blockage of ventilating parts.         

2) Clean the equipment with a clean soft cloth. Do not use isopropyl alcohol or any other cleaning agent.
3) Fusible resistor must not be replaced by operator. 

2

UTC-122,222

95mm  -  3.75 inches

85mm  -  3.34 inches

136mm  -  5.35 inches

120mm  -  4.72 inches

B

A

F

E

MODEL

A

96mm

96mm

92mm

92mm

3mm

50mm

B

C

D

E

F

DIMENSIONS

MODEL

A

72mm

72mm

68mm

68mm

3mm

85mm

B

C

D

E

F

DIMENSIONS

C

C

D

D

E

F

B

A

ENT

SET

UTC 122

TUNE

ºC

PV

SV

 



SET

  ENT

UTC 222

R1

R2

TUNE

PV

SV

ºC

 



Summary of Contents for UTC-122

Page 1: ...ve As per request Temperature Humidity 1st Output for Heating 1Relay 1C O 230V AC 5A Or SSR 12V DC Approx 30mA 2nd Output for Cooling 1Relay 1C O 230V AC 5A 100 to 250V AC 50 60 Hz Approx 4VA IP 65 Front side AS per IS IEC 60529 2001 0 C To 55 C Up to 95 RH Non Condensing Model Display Size HXWXD Panel Cutout Input Temperature Range Control Action UTC 122 96 X 96 X 50 mm 92 X 92 mm 68 X 68 mm 72 X...

Page 2: ... 1 Press key to go parameter setting 3 Press key to save change in setting 4 Press key for 6 sec to start stop PID AUTO TUNING 5 Press key for 3 sec to go to factory setting mode SET ENT 2 Press or key to change value or to select option Basic Configuration Set Point Setting Key Operation UTC 122 222 Press key to Save Exit ENT Control Action PID ON OFF Relay2 Mode TP ON OFF Set2 Mode Relative Indi...

Page 3: ...apply factory set values as shown in table nO press key to escape from factory setting Press key for 3 sec UTC 122 222 PV SV Press key to save exit ENT Press key SET Manual Reset Proportional Band Integral Time Derivative Time Cycle Time PID Parameters ON OFF Parameters Hysteresis 1 Cool HYS Offset 20 0 C to 20 0 C 20 C to 20 C CT 4 sec to 99 sec 4 sec to 99 sec IT 0000 to 9999 0000 to 9999 Hyster...

Page 4: ...in case the terminals do not remain accessible to the end user after installation and internal wiring 2 Do not allow pieces of metal wire clippings or fine metallic fillings from installation to enter the product or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator 3 Circuit breaker or mains switch must be installed between power source an...

Reviews: